Scope Of Delivery - ProMed 4030 SX Instrucciones De Empleo

Lima eléctrica con aspiración
Ocultar thumbs Ver también para 4030 SX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
D
EVICE INFORMATION
Before operating the unit for the first time, please check that all contents have been delivered and that the line
voltage is correct. This is done by checking whether the line voltage required for the unit (you can find this
information on the specification plate) corresponds to the local power supply (operating voltage of 230 V ~
connected to a correctly installed wall socket with a supply voltage of 230 V ~; operating voltage of 115 V
~ connected to a correctly installed wall socket with a supply voltage of 115 V~).
Be careful when positioned on ground level and make sure that the ventilation slots on the rear panel are
not obstructed. Also there should be sufficient distance at the back to allow sufficient air circulation. The
environment should be dry and at normal temperature (do not place near to the heat sources or steam
jets).
The device Promed 4030-SX2 is suitable with the appropriate abrasives ideal for manicure and
pedicure, as well as for the medical cosmetic foot and nail care
The Promed 4030-SX2 unit uses a high performance motor. The electronic speed control is used
to smoothly set the speed of the grinding head. The unit can rotate clockwise or counterclockwise
(switchable).
The grinding head holder is able to fixate all commercial grinding heads with standardized dental size
shafts of 2.332 to 2.350 mm (0.091 - 0.093 inches). Please use only high-quality grinding heads with a
rounded shaft end and a shaft length of 28 - 36 mm to guarantee the longest life possible for the grinding
head holder!
The abrasives must always be inserted completely until the stop in the abrasive holder has been reached.
Always make sure that the grinding head does not come in contact with other objects when you lay the
handpiece down. There is a risk of the shaft becoming compressed and asymmetrical. Asymmetry in the
grinding head causes damage to the handpiece!
Grinding head bits are available at your local specialist retailer or Promed (www.promed.de).
The dust bag is intended for single use only (disposable product) and must not be emptied or used several
times!
Exposure to nail and skin dust may result in health risks. Wearing face/mouth protection and gloves is
recommended for reasons of hygiene.
To ensure hygienic operation, the grinding heads must be disinfected after use.
The handpiece may only be disinfected using disinfectant wipes.
Information about suitable disinfectants and products can be obtained from Promed.
For disinfection of instruments and grinding heads: Promed Pure ID (Product No. 330810)
For disinfection of surfaces and devices: Promed Pure FD (Product No. 330815)
For disinfection and cleaning of instruments and grinding heads:
Promed UC-50 (Product No. 330210)
If required, you can buy replacements of the handpiece (item no. 204002) as well as the dust bag (pack
of 10: item no. 195870, pack of 20: item no. 195871, pack of 50: item no. 195872) from Promed.

Scope of delivery:

1x device 4030-SX2 with hose suspension (item 204006)
1x Handpiece Pom (item 204002)
5x Dust bag
1x Handpiece tray
1x Collet cleaning drill
1x Instructions with service / repair order
/
SCOPE OF DELIVERY
/
ACCESSORIES
DE
EN
FR
IT
ES
NL
RU
PL
SE
FI

Publicidad

Tabla de contenido
loading

Tabla de contenido