ProMed 4030 SX Instrucciones De Empleo página 23

Lima eléctrica con aspiración
Ocultar thumbs Ver también para 4030 SX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
O
PERATING THE UNIT
I.
Changing the dust filter:
Turn the device off and pull out the tube (G) and the power plug. Remove the cover (F) from the casing
by pulling gently on the extendable handle (B). Now hold onto the filter bag firmly with one hand and
the pull the tube supports out of the opening. Remove the full filter bag and replace it with a new one.
The filter is installed by reversing these steps. Ensure that the new filter is not damaged (i.e. the welds are
perfect).
If the suction capacity drops noticeably, but at the latest if the filter is filled by 2/3, the filter should
be replaced! This is the only way to ensure full suction capacity and prevent the suction turbine from
overheating due to an insufficient supply of air!
Attention:
Only use original dust bags!
Attention:
The filter bag is intended for single use only (disposable product) and must not be emptied or used
several times!
Attention:
If a filter bag is torn during operation and if there is a lot of grinding dust in the filter chamber ,
under no circumstances should you continue to use the device, since otherwise the suction turbine
may be damaged . In this case, immediately send the device back for servicing!
Attention:
If the filter is too full, there is a risk of the filter bursting! This may result in grinding dust entering the
turbine and destroying it.
Attention:
Every day before starting work, check the condition of the filter bag (fit and filling level).
Replace the filter bag according to the instructions above if necessary. Replacing the filter in good
time extends the service life of the suction turbine.
Attention:
Commercial anti-odour cartridges (vacuum cleaner accessories) can be inserted through the dust
bag opening and prevent unpleasant odours to a large extent.
Attention:
Never transport the device with a filled dust bag! The same applies if you store the device, do not
use it for a longer period of time or want to send it in for servicing.
M. Control system for recommended dust bag replacement
The Promed 4030-SX2 is equipped with a dust bag control system: It indicates the remaining operating
time with the dust bag used and can be adjusted individually by the user based on personal experience.
The remaining operating time with the dust bag used can be requested at all times by pressing the button
(R) and then appears briefly on the display:
In the dust bag symbol, the current turbine temperature in the suction chamber is displayed.
If the operating time for a dust bag has expired, necessary replacement of the dust bag is indicated by
means of a warning message on the display. The symbol is shown until the dust bag has been replaced.
After the dust bag has been replaced, the control system must be "reset". To do this, press the button (R)
for approx. 4 seconds. The "resetting" process is confirmed by a signal sound.
DE
EN
FR
IT
ES
NL
RU
PL
SE
FI

Publicidad

Tabla de contenido
loading

Tabla de contenido