COMPACT 3.0
Control Panel
5
4
1.- On/off: Switching the unit On - Off and mode selection F4 / F0 / F1 / F2 / F6
2.- Temperature selector (15/ 27 ºC - 59/80º F), Remote control programmation,
Farenheit degrees and Air Speed: Ambient temperature control and centrifugal
blower speed (between 1st and 5th speed) manual mode only.
3.- Display: Screen showing the function selected and the status of the equipment.
4.- Led : On - indicates intermediate power f0 , f4
5.- Led : On - indicates maximum power P0 , P4
•
On connection, the equipment checks the leds and
turns off.
Special display messages (please check Trouble Shooting):
Lb: " Low Battery" (the unit will beep for a few moments and the unit will turn off).
EO :
Poor return air sensor wire contact or return air sensor faulty.
E2 :
Electrofan or blower failure.
E6 :
Poor anti-freeze sensor wire contact or anti-freeze sensor faulty.
E9 :
Compressor protection (cabin tilted).
Turning the Equipment On
To turn the Compact 3.0 N&D unit on, press the On/off key
start up on the F4 Function (Automatic Function).
To change the function, hold down the On/Off key
displayed, release the key on obtaining the desired function.
ºC
3
ºF
TEMP
9
+
2
-
- 2 appears on the screen and
. The different functions will be
®
ON/OFF
1
. The unit will always
EN