Analogic Dosing Pumps Eone Ma Series; Operating Principles; Technical Characteristics; Reference Standards - Etatron eOne MA Normas De Instalación, Uso Y Manutención

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ANALOGIC DOSING PUMPS EONE MA SERIES

Operating principles

Dosing pump operation is ensured by a PTFE (teflon®) membrane mounted on the piston of an electromagnet. When
the piston of the electromagnet is attracted, pressure is produced in the pump head and liquid is ejected from the discharge
valve. Once the electrical impulse has terminated a spring brings the piston back to its original position and liquid is called in
through the suction valve. Due to this simple operation of the pump, no lubrication is needed and maintenance is reduced to
nearly zero. The materials used to manufacture the pump make it fit for use even with particularly aggressive liquids. The
dosing pump has been designed for flow rates starting from 1 to 30 l/h and pressures from 4 to 20 bar (depending on pump
type).

Technical Characteristics

Reference Standards

The dosing pump is in accordance with the following directives:
Tipe
0110
0216
0420
0607
0710
1012
1505
2007
3005
0210(*)
0507(*)
(*) only model BASIC
24 ENGLISH
Equipment manufactured according to CE regulation
Anti acid plastic casing
Control panel protected by adhesive film resistant to atmospheric agents and UV rays
Power supply: extended range 90 – 260 Volt 50-60 Hz
IP65 protection level
Environmental conditions: closed environment, altitude up to 2000 m, ambient temperature from 5°C to
40°C, maximum relative humidity 80% up to a maximum of 31°C (linear decrease down to 50% at 40°C).
Classification with respect to protection against indirect contacts: CLASS I (the equipment is supplied with an
electrical protection conductor).
2006/95/CE:
2004/108/CE:
Max Flow rate
mL/col
L/h
mL/min
po
16,66
0,09
1 (0.26)
2 (0.53)
50,00
0,11
4 (1.06)
83,33
0,22
6 (1.59)
83,33
0,33
7 (1.84)
133,33
0,39
10 (2.64)
166,66
0,56
15 (3.96)
250,00
0,83
20 (5.26)
333,33
1,11
30 (7.92)
500,00
1,66
2 (0.53)
33,33
0,18
5 (1.32)
83,33
0,46
" low tension"
" electromagnetic compatibility"
Max
Stroke
Pressure
[imp/1']
[bar]
0 – 180
10 (145)
16 (232)
0 – 300
20 (290)
0 – 300
7 (101)
0 – 300
10 (145)
0 – 300
12 (174)
0 – 300
5 (72)
0 – 300
7 (101)
0 – 300
5 (72)
0 – 300
10 (145)
0 – 180
7 (101)
0 - 180
Standard
Power
power supply
adsorbed
[W]
19
21
21
28
26
36
100 -250 V / 50-60 Hz
26
32
32
36
36
Current
Net
MAX
weight
[A]
[kg]
1,4
3,0
1,4
3,5
1,4
3,0
2,0
4,5
1,8
3,5
1,8
4,5
1,8
3,5
1,9
4,7
1,9
4,7
1,6
3,0
1,6
3,0

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

011002160420060707101012 ... Mostrar todo

Tabla de contenido