14-CODE MEANING

Code
Temperature-controlled blast chilling or deep freezing not concluded within
maximum duration alarm
TiME
(HACCP alarm)
Main consequences:
the device will memorize the alarm
Minimum temperature alarm
Solutions:
AL
check the temperature of the cabinet
Main consequences:
the device will continue to operate normally
Maximum temperature alarm (HACCP alarm)
Solutions:
AH
check the temperature of the cabinet
Main consequences:
the device will memorize the alarm
Door open alarm
Solutions:
Id
check the door conditions
Main consequences:
buzzer activated
High pressure alarm
Solutions:
clean the condenser filter
HP
clean the condenser
Main consequences:
buzzer activated
Power cut alarm (HACCP alarm)
check the device-power supply connection
PF
Main consequences:
the device will memorize the alarm
Condenser overheated alarm.
Solutions:
COH
check the temperature of the condenser
Main consequences:
the condenser fan will be switched on
Compressor blocked alarm.
Solutions:
check the temperature of the condenser
disconnect the device power supply and clean the condenser
CSd
Main consequences:
if the error occurs during the "stand-by" status, no operating cycles can be selected or
started
if the error occurs during an operating cycle, the cycle will be interrupted