Blast Chillers
Cabinet probe error.
Solutions:
Main consequences:
Pr1
Needle probe error.
Solutions:
Pr2
Solutions:
Evaporator probe error.
Pr3
Solutions:
Clock error
Solutions:
rtc
Main consequences:
50LIB055
check the integrity of the probe
check the temperature of the cabinet.
if the error occurs during the "stand-by" status, no operating cycles can be selected or
started
if the error occurs during blast chilling or deep freezing, the cycle will be interrupted
defrosting will never be activated
the door resistances will never be switched on
the minimum temperature alarm (
the maximum temperature alarm (
the same as the cabinet probe error (
information regarding HACCP alarms will not have been displayed.
if the error occurs during the "stand-by" status, temperature-controlled operating cycles
will be started by time-control
if the error occurs during needle probe heating, this operation will be interrupted.
the same as the cabinet probe error (
set the real date and time again
the device does not memorize the date or time at which the HACCP alarm occurred or
its duration
"AL"
code) will never be activated
"AH"
code) will never be activated
"Pr1"
code) but relative to the needle probe. ll
"Pr1"
code) but relative to the evaporator probe.
26