GYS COMBIDUCTION AUTO 50 LG Manual De Instrucciones página 34

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
Operating manual
CONSUMABLES
Cloths for induction heaters
Fibreglass cloths used on glass inductors, and also on seized inductors, can wear out from repeated use and from rub-
bing against the parts to be heated. If these cloths need to be replaced, GYS has provided the required kits' reference
numbers below.
053854
FIVE-PIECE GLASS INDUCTOR MAINTENANCE KIT & GLUE
059108
ONE INDUCTOR PROTECTION GLOVE & GLUE
Freeze spray
This freeze spray is particularly useful for unpainted, dent-removal operations and for cooling heated parts.
048898
SET OF 12 COOLING SPRAYS -50°C / 400 ML
DEFAULT CODES
CODE
MEANING
E - 1
Pedal activated on power-up.
E - 2
Glass-inductor button activated on power-up.
E - 3
Front panel ON/OFF button pressed at power-up.
E - 4
Overcurrent in the inductor (either due to being too hot or a short circuit).
E - 5
Faulty inductor (cut or disconnected wire).
NO– ACC
Attachment not connected.
AC -
Attachment not recognised.
«DRAINAGE» MODE
This function can only be used if the heating process is not activated (green button off).
1. Press the inductor-change button (11), the pump will stop and the LED (10) will light up.
2. Place the lance in its holder. Put the cable on the ground to avoid fluid loss.
3. Unscrew the inductor with the 27 key (supplied with the product).
4. Press and hold the heat-enable button (2) for three seconds until it lights up.
5. Position the lance over a container with a capacity of at least 10 litres.
6. Press the lance button (12). The pump will run either until the flow rate falls below one litre/min or for two minutes.
The display shows the flow rate in decilitres per minute. To stop the pump during a cycle, press any button.
7. To completely drain the coolant system, blow (30PSI ≈ 2 bar) into the lance's tip until you hear air or see coolant
spraying out of the tank.
8. To drain the remaining liquid from the bottom of the
tank, use a vacuum pump or tilt the product towards
the front.
10. To refill the coolant, follow the instructions for the machine's first use.
It is advisable to change the coolant every year, otherwise the COMBIduction lance will be damaged.
It is preferable to use the special welding coolant offered with the Combiduction (see the section entitled 'Maintenance').
COOLING SYSTEM AND «FORCED COOLING» MODE.
When the coolant's temperature reaches 35°C (95°F), the fan will start. As soon as its temperature drops below 35°C,
it will switch off again.
During long heating periods, the COMBIDUCTION has a forced cooling mode. To switch it on:
1. Flip the main switch (1) to the ON position.
The machine carries out its start-up phase for two seconds.
2. Press the heat-release button (2). The heat-release button (2) and the LED indicator light (12) will light up, indicating
that the product is now ready to heat.
3. Press and hold (>3 seconds) the inductor-change button (11). This will activate the «Forced Cooling» mode.
The fan will then start automatically. The message «Fan ON» will appear on the display screen.
To stop the «Forced Cooling» mode, repeat step three. The message «Fan OFF» will appear on the display screen.