MAINTENANCE

General guidelines

• It is advised to change the coolant every year to avoid damaging the COMBIDUCTION machine's lance. Before add-
ing the coolant, dust the product and thoroughly check for leaks.
• Preferably use the special welding coolant supplied with the COMBIDUCTION machine. Do not use automotive cool-
ant. Only use coolants with low electrical conductivity.
• Regularly check that the tiller bolts are tightly screwed and that the electrical power connections are in good condition.
recommended torque for power screws:
Screw size
M5
Material
steel
Torque
4 Nm
• It is essential that the product's maintenance is carried out by authorised, qualified personnel who are aware of the
recommendations outlined in this manual.
• Never clean, oil or carry out maintenance on the product whilst it is in operation.
• Before undertaking any maintenance, set the On/Off switch (1) to the «0» position to switch off the product. Then,
disconnect it from the mains supply to avoid electric shocks or other hazards resulting from improper handling.
• Do not wear rings, watches, jewellery or hanging clothes such as ties, ripped clothing, scarves, unbuttoned jackets or
open zips that could be caught whilst working.
• Instead, wear protective clothing specifically designed to prevent accidents, such as : non-slip shoes, hearing protec-
tion, safety glasses and safety gloves, etc.
• Never use petrol or flammable solvents to clean the product. Use water instead and, if necessary, non-toxic comme
cial solvents.
• After maintenance, always reassemble the product's metal casings before restarting the machine.
• The ferrite on an inductor can be replaced if damaged.
To replace it, you need to:
- remove the protective cover.
- use a hot-ait paint stripper helps to remove the ferrite from the copper.
- clean the copper thoroughly.
- glue down the new ferrite with the specially-designed ferrite resin.
- position the new ferrite with its covering.
- wait for the adhesive to set completely before using the inductor.

Preventive maintenance

Thorough inspections at regular intervals are necessary to detect and eliminate defects quickly, so that they do not
cause damage to the appliance.
Whenever you need to use the COMBIDUCTION equipment, first check the appliance's safety features
and any anomalies that may affect the machine's correct operation. Check daily for signs of wear.
The operational safety of the product can only be guaranteed if repairs are carried out using original
spare parts and if the maintenance instructions are properly followed.
After each use, when the product is switched off, it must be immediately cleaned to remove any dust or
dirt that may reduce the efficiency of the ventilation system and also affect the product's correct functio-
ning and its life span.
Before each use, check that the machine is functioning properly, along with the safety equipment and all
the electrical connection cables.
Carry out periodic visual checks for fluid leaks and check that vents are not obstructed.

ELECTRICAL CONNECTIONS

This product is designed to operate with a single-phase mains voltage of 165 V to 265 V.
For 230 V single-phase electrical installations:
COMBIDUCTION
COMBIDUCTION
P1 - 230 V
N
Earth
Translation of the original
instructions
M6
M8
M10
steel
brass
brass
6 Nm
7 Nm
7 Nm
Gas 1/4
hose clamp
3/8 Gas
copper
2.5 Nm
4 Nm
7 Nm max
For three-phase electrical installations:
P3
COMBIDUCTION
COMBIDUCTION
P2
P1 - 230 V
N
Earth
COMBIDUCTION AUTO 50 LG
M28
M32
Inductor 16/22
copper
copper
by hand,
7 Nm max
4 Nm max
35