BATTERY CHARGE WARNINGS
Since your UPS can provide battery backup only for as long as the batteries remain
charged, these warnings should be acted on immediately.
Battery Charge Warning
Battery charge nearly depleted
AC/DC charger not operating

OPERATION UNDER SHUTDOWN

Your UPS will shut down and the LCD will display a message if it detects one of the
following conditions. Note: For all conditions, the "Input," "Output" and "Bypass" LEDs
will be illuminated.

OPERATION OF MANUAL BYPASS SWITCH

Turn this switch to "BY-
PASS" before performing
any maintenance on the
UPS with the connected
load supported. Connected
equipment will receive
filtered AC mains power,
but
battery power in the event
of a blackout.
SWITCHING UPS TO "BYPASS" MODE
• Turn the "ON/OFF" Switch OFF. (LCD will read "ON BYPASS.")
• Turn the "Manual Bypass" Switch clockwise from NORMAL to BYPASS.
• Turn the AC Input Circuit Breaker OFF.
• Open battery fuse holders and remove the battery fuses from all battery packs
SWITCHING UPS TO "NORMAL" MODE
• Replace all battery fuses in the battery fuse holders and close the
• Turn the AC Input Circuit Breaker ON.
• Turn the "Manual Bypass" Switch counterclockwise from BYPASS
• Turn the "ON/OFF" Switch ON.
12
All manuals and user guides at all-guides.com
Condition
Extended Overload (>150%)
Output Short Circuit
Remote Shutdown Command
(FROM DB9 INTERFACE)
Remote Shutdown Command
(from RJ11 interface)
Internal Faults
will
not
receive
and from all SU6K models.
battery fuse holders.
back to NORMAL.
LCD Display Message
BATTERY LOW
CHARGER FAILURE!
LCD Display Message
OVERLOAD 150%
SHUT DOWN
SHORT CIRCUIT!
SHUT DOWN
REMOTE
SHUT DOWN
EMERGENCY STOP!
SHUT DOWN
INVERTER TOO LO
SHUT DOWN
INVERTER TOO HI
SHUT DOWN
DC BUS +/- HIGH/LOW
SHUT DOWN
OVERTEMPERATURE
SHUT DOWN
A C IN P U T
U P S
U P S P O W E R
IN P U T B R E A KE R
¡¸LO N G B A C K -U P
SUBP CHARGER OUTPUT
B A TTER Y
STD.
TIM E C H A R G E R
BATTERY
C AB IN E T
M A N U A L B Y P A S S S W IT C H
O U T P U T B R E A K E R
¡¸ LO N G B A C K -U P T IM E M O D E L S C O N T A IN L O N G B A C K -U P T IM E C H A R G E
SUBP CONNECTED MODELS CONTAIN SUBP CHARGER
¡¸ IN T H E C O N F IN E D A R E A , A LL C O M P O N E N T S A R E E L E C T R IC IS O L A T IO N
CURRENT IN THE AREA MARKED BY THE DASHED
W IT H A C LIN E
OUTLINE. ALL COMPONENTS ARE ELECTRONICALLY
ISOLATED FROM THE AC LINE.