EdmoLift Products Manual
1 Actions after use
Platforms can be left in the raised position unless this creates inconvenience or hazard. It is therefore recommended
that the platform be lowered to the bottom position when work is finished.
If the platform is left in the raised position the level can change for several reasons:
The oil volume changes due to temperature variations.
Leakage in valves, hoses or fittings.
Leakage in a cylinder
When there is a risk of unauthorized use the isolator should be locked in the OFF position.
The control unit is also lockable with a padlock.
Control unit
2. Emergency Stop
EdmoLift products are provided with an Emergency Stop button on the control unit. Optional Emergency Stopping
devices that are easily accessible from other locations, can also be provided. When an Emergency Stop button is
pressed all electrically controlled movements are stopped. The Emergency Stop button is red and clearly visible.
When the reason for activating the Emergency Stop has been established and safe working conditions prevail, the
Stop button is turned clockwise to release the button and revoke the stop.
3. Armlifts
If lifting is started from the bottom level, the platform will remain with the same tilting angle as the last lowering motion.
It may therefore be necessary to initially tilt the platform to 0° tilting, in order to prevent unrequired tilting when work is
started.
NOTE! The platform has a sideways movement up to
440mm, dependent on the lift stroke.
UP
Copyright © EdmoLift AB 2004-2007
All rights reserved. No part of this publication may be reproduced, stored in a retrie-
34
val system, or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording or otherwise without the permission of the publisher.
DOWN
TILT DOWN
2005-02-01
5°
45°
440
TILT UP
EdmoLift AB
Jägaregatan 11
S-871 42 HÄRNÖSAND, SWEDEN
85921 GB
EMERGENCY STOP
Tfn. +46 (0)611-83 780
Fax. +46 (0)611-51 15 80
info@edmolift.se