ATTENTION, before entering a PIN-protected SIM, access this page and enter the correct PIN
otherwise you run the risk of locking the SIM with an incorrect pin, since the system executes the
three attempts allowed consecutively.

16.1.2. Display-Modem communication control page.

Use the F7
key to access a page where the communication strings between the two devices are displayed, this is only
useful for maintenance purposes.

16.1.3. Control and status messages.

All messages that the modem can send and receive are coded and constructed so as to have a unique
code and, if available, text messages of the selected language, the table of messages divided into 4
categories is shown below:
Statuses, they start with the letter S and are messages that the machine sends independently to all
numbers enabled in the list:
S001- On
S002- Automatic shutdown sequence started
S003- Running
Alarms, they start with the letter A and are messages sent by the machine (to all numbers enabled in the
list) in case of a new alarm
A001 Low battery
A002 I/O module fault
A003 Litre counter sensor error
A004 Speed Alarm
A005 No pressure
A006 Work cycle end
A007 Pressure transducer error
A008 Modem error
A009 Machine slipping serious error
A010 Chain slipping control - check the chain
A011 Chain sensor error
A012 Incorrect machine configuration data
Commands, they start with the letter C and are only accepted if the transmission number is present in the
list and must ALWAYS be preceded by the character #, e.g. you can write either "# C001" or "# DATA" to
obtain the status of the machine.
C001
DATA
Machine status request
C002
STOP
Machine stop request
C003= SPEED=
Followed by a numerical value changes the speed of the active sector
C004= RAIN=
Followed by a numerical value changes the rainfall of the active sector
C005
STARTS
Followed by a value changes the operating mode speed and forces a single sector to
the written speed.
C006
STARTP
Followed by a value changes the operating mode to rainfall and forces a single
sector to the written water quantity.
C007
TIME
Followed by two numbers separated by a space sets the initial and final time.
Responses (only to the number that sent the command) to the commands/requests that begin with the