Electrical Characteristics, Sensitivity 10Mv/A (Pac 26) - Chauvin Arnoux PAC 25 Manual De Instrucciones

Pinza amperimétrica ca/cc
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.3. ELECTRICAL CHARACTERISTICS, SENSITIVITY 10MV/A (PAC 26)

Output impedance: 215 W
Specified
measurement range
Intrinsic uncertainty
Phase error (45 to 65Hz)
Specified measurement range
Phase shift
Typical amplitude error versus frequency curve at 60Hz
Error (%)
0
-5
-10
-15
0,1
Typical amplitude error versus frequency curve at DC
Error (%)
0
-5
-10
-15
0,1
1
0.5 to 40Aac/dc
≤ ± (3%L + 5 mV)
1
10
10
40 to 100Aac/dc
1 to 100Aac
≤ ‑2°
Current (A)
100
Current (A)
100
1000
33
≤ ± 1.5%L
100 to 150Adc
≤ ± 1.5%L

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pac 26

Tabla de contenido