Technical description
Control elements in the connection box
The connection box is located on the generator behind the cover.
No. in
fig. 4,
Description
page 4
1
Main switch
2
12 V fuse (main circuit)
3
Spare fuse
4
eCore connection
5
Battery positive terminal
connection
6
Ground terminal
7
Orange wire
8
Plug for fuel reserve signal
Control elements in the control panel
I
NOTE
You find detailed information about the control panel and how to
set the generator in the operating manual of the eCore.
28
ePower T, ePower T LPG
Switches the generator to standby (ready
for use with the Dometic eCore) or no
function.
This fuse protects the low power 12 V
circuit inside the ePower T. It will blow if
excess current is present. It can be
replaced with the spare fuse in the holder
below.
This fuse is a spare. It can be used to
replace the blown 12 V fuse.
These are the connection points to the
Dometic eCore (via the ePower cable).
This terminal should be connected with a
power cable to the positive terminal of
the battery.