Setting Up; Controls On The Front Panel - Stel TIG μP 261H 1f Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
TIG µP 261H - 263H
COD. 6907600050

5.0- SETTING UP

5.1- CONTROLS ON THE FRONT PANEL

1
2
3
V (D)
4A
2T
4B
4T
4C
4D
4E
SELECT
MODE
4
MIN
A
MAX
5
HF ON
6A
6
STOR. JOB
7A
7
8
14
9
10
1
Machine live indicating led
2
Weld enable indicating led
3
Thermal alarm indicating led
4
Mode selection button
4A
ELECTRODE mode selecting led
4B
TIG 2 TIMES mode selecting led
4C
TIG 4 TIMES mode selecting led
4D
Tig SPOT mode selecting led
4E
Tig RESET mode selecting led
5
Current regulation/ selected functions encoder
6
Remote control selection and regulation button
6A
Remote control selection and regulation led
7
High frequency start selection button
7A
High frequency start selection led
8
Slope up, spot-weld time regulation button
STEL s.r.l. – Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
FAX +39 444 639641 – E-mail:stelgroup.com
http: www.stelgroup.it
TECHNICAL DESCRIPTION
PULSE MODE
A (F)
ON
JOB MODE
SET JOB
ENTER\EXIT
%
t2
F
MIN
MAX
A
t
t
1
2
%
%
D
MIN
MAX
C od. 6603230000
15
16
11
12
13
9
Negative polarity connecting socket
10
Torch button connector
11
Gas coupling
12
Remote control connector (CAD)
13
Positive polarityconnecting socket
14
Slope down regulation button
15
Base current regulation button
16
Pulse duty cycle regulation encoder
17
Post Gas regulation button
17a
Post-gas indicating led
18
Pulse frequency regulation
19
Pulse mode enable button
19a
Pulse mode indicating led
20
Welding parameters display
21
Welding parameters display
ENGLISH
5.0- SETTING UP
5.1- CONTROLS ON THE FRONT PANEL
21
1
2
20
3
19
4A
4B
19A
4C
4D
18
4E
17
4
17A
5
6A
6
1
Machine live indicating led
2
Weld enable indicating led
3
Thermal alarm indicating led
4
Mode selection button
4A
ELECTRODE mode selecting led
4B
TIG 2 TIMES mode selecting led
4C
TIG 4 TIMES mode selecting led
4D
Tig SPOT mode selecting led
4E
Tig RESET mode selecting led
5
Current regulation/ selected functions encoder
6
Remote control selection and regulation button
6A
Remote control selection and regulation led
7
High frequency start selection button
7A
High frequency start selection led
8
Slope up, spot-weld time regulation button
STEL s.r.l. – Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
FAX +39 444 639641 – E-mail:stelgroup.com
43
http: www.stelgroup.it
TIG µP 261H - 263H
COD. 6907600050
V (D)
A (F)
2T
JOB MODE
4T
SET JOB
ENTER\EXIT
%
t2
SELECT
MODE
MIN
A
MAX
A
HF ON
t
t
1
2
%
%
STOR. JOB
7A
7
8
14
15
9
10
11
12
9
Negative polarity connecting socket
10
Torch button connector
11
Gas coupling
12
Remote control connector (CAD)
13
Positive polarityconnecting socket
14
Slope down regulation button
15
Base current regulation button
16
Pulse duty cycle regulation encoder
17
Post Gas regulation button
17a
Post-gas indicating led
18
Pulse frequency regulation
19
Pulse mode enable button
19a
Pulse mode indicating led
20
Welding parameters display
21
Welding parameters display
TECHNICAL DESCRIPTION
21
PULSE MODE
20
19
ON
19A
18
F
17
MIN
MAX
17A
D
MIN
MAX
C od. 6603230000
16
13
43