4.0 SETTING UP

4.1 CONTROLS ON THE FRONT PANEL

1
2
3
V (D)
4A
2T
4B
4T
4C
4D
4E
SELECT
MODE
4
MIN
A
MAX
5
HF ON
6A
6
STOR. JOB
7A
7
8
14
9
10
1
Machine live indicating led
2
Weld enable indicating led
3
Thermal alarm indicating led
4
Mode selection button
4A
ELECTRODE mode selecting led
4B
TIG 2 TIMES mode selecting led
4C
TIG 4 TIMES mode selecting led
4D
Tig SPOT mode selecting led
4E
Tig RESET mode selecting led
5
Current regulation/ selected functions encoder
6
Remote control selection and regulation button
6A
Remote control selection and regulation led
7
High frequency start selection button
7A
High frequency start selection led
8
Slope down regulation button
9
Gas coupling
STEL s.r.l. – Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
FAX +39 444 639641 – E-mail:stelgroup.com
http: www.stelgroup.it
TECHNICAL
DESCRIPTION
PULSE MODE
A (F)
ON
JOB MODE
SET JOB
ENTER\EXIT
%
t2
F
MIN
MAX
A
t
t
1
2
%
%
D
MIN
MAX
C od. 6603230000
15
16
C od. 6627700010
11
12
13
10
Negative polarity connecting socket
11
Torch button connector
12
Positive polarity connecting socket
13
Remote control connector (CAD)
14
Final Current regulation button
15
Base current or postgas regulation button
16
Balance regulation encoder
17
Pulse regulation button
17a
Pulse indicating led
18
AC Frequency regulation
19
AC Pulse mode enable button
19a
AC Pulse mode indicating led
20
Welding parameters display
21
Welding parameters display
ENGLISH
4.0 SETTING UP
4.1 CONTROLS ON THE FRONT PANEL
21
1
2
20
3
19
4A
4B
19A
4C
4D
18
4E
17
SELECT
4
17A
5
6A
6
1
Machine live indicating led
2
Weld enable indicating led
3
Thermal alarm indicating led
4
Mode selection button
4A
ELECTRODE mode selecting led
4B
TIG 2 TIMES mode selecting led
4C
TIG 4 TIMES mode selecting led
4D
Tig SPOT mode selecting led
4E
Tig RESET mode selecting led
5
Current regulation/ selected functions encoder
6
Remote control selection and regulation button
6A
Remote control selection and regulation led
7
High frequency start selection button
7A
High frequency start selection led
8
Slope down regulation button
9
Gas coupling
STEL s.r.l. – Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
FAX +39 444 639641 – E-mail:stelgroup.com
45
http: www.stelgroup.it
TIG µP 203H-353H AC/DC
COD. 6902500070
V (D)
A (F)
2T
JOB MODE
4T
SET JOB
ENTER\EXIT
%
t2
MODE
MIN
A
MAX
A
HF ON
t
t
1
2
%
%
STOR. JOB
7A
7
8
14
15
9
10
11
10
Negative polarity connecting socket
11
Torch button connector
12
Positive polarity connecting socket
13
Remote control connector (CAD)
14
Final Current regulation button
15
Base current or postgas regulation button
16
Balance regulation encoder
17
Pulse regulation button
17a
Pulse indicating led
18
AC Frequency regulation
19
AC Pulse mode enable button
19a
AC Pulse mode indicating led
20
Welding parameters display
21
Welding parameters display
TECHNICAL
DESCRIPTION
21
PULSE MODE
20
19
ON
19A
18
F
17
MIN
MAX
17A
D
MIN
MAX
C od. 6603230000
16
C od. 6627700010
12
13
45