Operating the Pump While Running

If power is connected to the pump, pressing any of the
following buttons referred to in this section could result
in the motor starting. Failure to recognize this could result in personal injury or
damage to equipment.
Pressing the Display button will cycle through the current
parameters:
• Speed / %FL — current run speed or
percent flow
• Time — current time of day
• Duration — amount of time remaining at the
current PROGRAM
• Watts — amount of watts currently being
consumed
Pressing any of the PROGRAM Buttons ("1", "2", "3",
"Quick Clean") while the pump is running will act as a
temporary override. The pump will run the speed and
duration programmed for that button. Once completed the
pump will return to the appropriate point in the programmed
schedule.
Note: If PROGRAM speeds are adjusted while the pump is
running, the pump will run the entered speed for the rest of
the PROGRAM duration, but will not save the adjustments.
Exception: QUICK CLEAN Speed and Duration
adjustments will always be immediately saved.
Quick Clean
During a Quick Clean cycle, pressing "+" or "-" will change
the speed accordingly. Pressing Quick Clean within 10
seconds after will allow for adjustment of the Quick Clean
duration using the "+" and "-" arrows. These changes will be
saved immediately and are the new settings for Quick Clean.
Pressing Quick Clean again will cycle through the two Quick
Clean settings. The pump will exit editing mode if no buttons
are pressed within 10 seconds.
Note: While in keypad lockout mode the quick clean
feature is enabled and the "+" and "-" buttons can be used
to make temporary changes.
A Quick Clean cycle can be stopped by pressing and holding
Quick Clean for 3 seconds. The pump will return to the
appropriate point in its 24-hour schedule.
When a connected control system is in Service Mode, a pump
connected via RS-485 can still run its Quick Clean program.
Once Service Mode is enabled the pump display will flash
between "SEr" and the current Quick Clean speed (Figure
14). Once Service Mode is disabled the pump will resume
normal operation.
Note: Quick Clean speed will read 0 when Quick Clean is off.
Figure 14
XF
®
WHISPERFLO
VS and MAX-E-PRO
XF
®
VS Commercial Variable Speed Pump Installation and User' s Guide

Programming Quick Clean

The pump is equipped with a Quick Clean feature, which
can be engaged to temporarily run at higher or lower speeds
ranging from 300 to 3450 RPM.
At the end of a Quick Clean cycle, the pump will automatically
return to the appropriate point in its programmed schedule.
Note: Pressing and holding Quick Clean for more than
3 seconds will cancel a Quick Clean cycle. The pump will
then return to the appropriate point in its programmed
schedule.
TO PROGRAM QUICK CLEAN:
1. Press Start/Stop to stop the pump.
2. Press Quick Clean. The Quick Clean LED and "Spd
/ %FL" parameter LED will blink while editing. See
Figure 15.
3450
Figure 15
3. Use "+" and "-" to adjust the Quick Clean speed in RPM.
4. Press Quick Clean. The Quick Clean duration will
display. The "Duration" parameter LED will blink while
editing. See Figure 16.
2 : 00
Figure 16
5. Use "+" and "-" to adjust the Quick Clean duration in
hours and minutes.
Note: It is recommended that you do not set the Quick
Clean duration to 0 HRS. Setting the Quick Clean duration
to 0 HRS will prevent edits to the duration setting while the
motor is running. The motor will need to be stopped.
Note: Quick Clean duration does not affect the start or
stop times of the 24-hour schedule. For example, if Quick
Clean runs during a period overlapping with a later part of
PROGRAM 1 and an early part of PROGRAM 2, the start
time of PROGRAM 3 is not affected.