Technical Specifications; Declaration Of Conformity - STEINEL SensorLight L 30x S Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Adjusting the detection zone
The detection zone can be restricted to suit require-
ments. The shrouds supplied with the light can be
used to mask out as many lens segments as you
wish. This prevents the light from being activated
Manual override function
If a mains switch is installed in the mains supply lead,
the light is capable of the following functions in add-
ition to the simple ON/OFF function:
Sensor operation
1) Switch light ON (when light is OFF):
Turn switch OFF and ON once.
Light stays on for the period selected.
2) Switch light OFF (when light is ON):
Turn switch OFF and ON once.
The light goes out or switches over to sensor mode.

Technical specifications

Wattage:
Voltage:
Angle of coverage:
Sensor reach:
Time setting:
Twilight setting:
Programme setting:
Manual override:
VDE protection class:
Operation/Maintenance
The SensorLight is suitable for switching light on
automatically. Weather conditions may affect the way
the SensorLight functions. Strong gusts of wind, snow,
rain or hail may cause the light to come on when it is

Declaration of conformity

This product complies with the European Directive on
Low-Voltage Appliances, 73/23/EEC and the EMC
Directive 89/336/EEC.
unintentionally, e.g. by cars, passers-by etc. and
allows you to target danger spots. The shrouds can
be cut along the pre-grooved vertical divisions. Then
they simply clip onto the lens.
Manual override
1) Activate manual override:
Turn switch OFF and ON twice. The light is set to stay
on for 4 hours (red LED lights up behind lens). Then it
returns automatically to sensor mode (red LED off).
2) Deactivate manual override:
Turn switch OFF and ON once. The light goes out or
switches over to sensor mode.
Important:
The switch should be actuated in rapid succession
(in the 0.5 – 1 sec. range).
100 watts max. / E 27, filament bulb or
20 watts max., low-energy lamp (not for L 30x S)
Note: only use low-energy lamp in conjunction with programme
230 – 240 V / 50 Hz
360° with 90° angle of aperture and sneak-by guard
8 max. all round
5 sec. – 15 min.
2 – 2000 lux
Standard programme, filament bulb:
1
Soft light start / no basic brightness
Comfort programme, filament bulb:
2
Soft light start + basic brightness
Comfort economy programme, filament bulb:
3
Soft light start + basic brightness to midnight *
Low-energy lamp programme:
4
no soft light start / no basic brightness
selectable (4 hours)
provided switch is connected in mains supply lead
IP 44 (splashproof)
not wanted because the sensor is unable to distin-
guish sudden changes of temperature from sources
of heat. The detector lens may be cleaned with a
damp cloth if it gets dirty (do not use cleaning agents).
- 13 -
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sensorlight l 7x5 sSensorlight l 7x6 sSensorlight l 9x5 s

Tabla de contenido