Service Tasks; Leak Test; Changing The Dryer Filter - Waeco AirCon Service Center ASC5100G Instrucciones De Uso

Estacion de mantenimiento de aire acondicionado
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ASC5100G
9

Service tasks

9.1

Leak test

Every six months carry out a leak test with an electronic leak detection
device.
9.2

Changing the dryer filter

1. In the basic menu, use the cursor keys  or  to select
"Free selection":
2. Press ENTER to confirm.
3. Skip the query requesting "CAR DATA".
4. Select "Rec/Recycling phase".
5. Set the "Pressure increase test time" to "1".
Press ENTER to confirm.
6. Deselect "Vacuum phase" using "No".
Press ENTER to confirm.
7. Deselect "Filling phase?" using "No".
Press ENTER to confirm.
8. Select "Process start ?".
Press ENTER to confirm.
The service hoses will now be drained and the AirConServiceCenter
basic menu will be activated. The compressor has produced a slight
internal vacuum so that the filter can be replaced with minimal refrig-
erant loss.
9. Switch off the unit.
!
CAUTION!
The following steps may only be performed by qualified personnel.
Wear protective gloves and goggles.
EN
All manuals and user guides at all-guides.com
Short selection
Free selection
Other selections
ENTER-OK
Service tasks
91

Publicidad

Tabla de contenido
loading