System with one tank, one circulating pump and four probes.
(No modulating circulating pump, Metering, With supplementary heating).
- Assigning of terminals and block diagram.
S4 S4 - V1 S3 S3 S2 S2 S1 S1
P1
S4
/
/
/
/
/
/
/
/
/
/
Symbol Description
P1 Solar circulating pump
S1 Probe PT 1000 Upper tank
S2 Probe PT 1000 Lower tank
S3 Probe PT 1000 Solar collector
S4 Probe PT 1000 Solar return
T1 Consent for suppl. heating
184
EN
/
/
/
/
/
/
/
S1
/
/
/
/
/
/
/
/
/
/
code 3542A420 - Rev. 00 - 12/2021
R3 R3 R2 N L N R1 N
/
/
/
/
/
/
/
/
/
/
S3
S2
/
/
/
/
/
/
/
ECOTRONIC HiTech
/
/
/
/
/
/
/
/
/
/
T1
/
/
/
/
230 Vac