List Of Parameters - Baxi PBM-i 20 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LIST OF PARAMETERS

Description
Enable domestic hot water set point: 0 = Economy, 1 = Comfort
Domestic hot water Economy set point
Domestic hot water Comfort set point
User password
Enable remote contact: 0= remote contact enabled, 1= remote contact disabled (selection from keypad only)
Automatic mode changeover set point in hEATING
Automatic mode changeover differential in hEATING
Automatic mode changeover set point in COOLING
Automatic mode changeover differential in COOLING
Type of outlet heater operation: 0 = Supplementary , 1 = Replacement
Type of boiler operation: 0 = Supplementary , 1 = Replacement
kA11 contact configuration: 0 = Domestic hot water recirculation, 1 = Dehumidifier
SA7 input configuration: 1= Switch
Ratio between system and room: 0 = Unit in room mode, 1 = Unit in independent mode
Installer password
Fixed water outlet temperature set point in hEATING zone LT3
Enable compensation curve in COOLING zone LT3: 0 = Disabled, 1= Enabled
Fixed water outlet temperature set point in COOLING zone LT3
Maximum outlet temperature set point limit in cooling mode (Tm1)
Minimum outside temperature corresponding to max. outlet temperature (Te1)
Zone LT3 compensation curve number
Enable room temperature influence on LT3 0= Disabled 1= Enabled
LT3 Room Authority
MINIMUM outlet set point limit for compensation curve in zone LT3
MAXIMUM outlet set point limit for compensation curve in zone LT3
Maximum outlet temperature set point limit in cooling mode (Tm1)
Minimum outside temperature corresponding to max. outlet temperature (Te1)
Minimum outlet set point limit in cooling mode (Tm2)
Minimum outside temperature corresponding to min. outlet temperature (Te2)
Enable compensation for room humidity, ZONE LT3: 0= Disabled , 1= Enabled
Room relative humidity value to start increasing water outlet temperature set point, ZONE LT3
Maximum outlet temperature hysteresis corresponding to 100% relative humidity
Minimum outlet temperature set point limit in cooling mode (Tm2)
Maximum outside temperature corresponding to min. outlet temperature (Te2)
Maximum outlet temperature set point limit in cooling mode (Tm1)
Minimum outside temperature corresponding to max. outlet temperature (Te1)
Minimum outlet temperature set point limit in cooling mode (Tm2)
Maximum outside temperature corresponding to min. outlet temperature (Te2)
Maximum outlet temperature set point limit in cooling mode (Tm1)
Minimum outside temperature corresponding to max. outlet temperature (Te1)
Minimum outlet temperature set point limit in cooling mode (Tm2)
Maximum outside temperature corresponding to min. outlet temperature (Te2)
Inside temperature to enable frost protection
Outside air temperature for frost protection
Activation of system pump operation at intervals: 0= system pump always on, 1=system pump operation at intervals
System pump curve number: 1= Curve 1, 2= Curve 2, 3= Curve 3, 4= Curve 4
System pump operating time in sniffing mode
System pump off time between one sniffing cycle and the next
Enable SYSTEM compensation curve 0= Disabled 1= Enabled
Fixed water outlet temperature set point in hEATING
Enable SYSTEM compensation curve: 0= Disabled, 1= Enabled
Fixed water outlet temperature set point in COOLING
Enable compensation for room humidity, SYSTEM: 0= Disabled , 1= Enabled
Room relative humidity value to start increasing water outlet temperature set point, SYSTEM
Maximum outlet temperature hysteresis corresponding to 100% relative humidity
SYSTEM compensation curve number
Enable contact as: 0= Alarm signal, 1= Dehumidifier, 3= Secondary circuit pump
Enable contact as: 0 = System pump, 1= System outlet electric heater, 1st stage, 4= Unit operating mode signal (cooling/heating)
Enable contact as: 0 = DhW recirculation, 1= Dehumidifier, 2= Secondary circuit pump, 3= Unit operating mode signal
(cooling/heating)
Enable the contact as: 0=Reduced electricity rate, 1=Stop operation due to excess power consumption
Enable compensation curve in hEATING zone LT3 0= Disabled 1= Enabled
Enable room temperature influence on SYSTEM 0= Disabled 1= Enabled
SYSTEM Room Authority
Minimum set point limit for SYSTEM curve
Maximum set point limit for SYSTEM curve
Enable compensation curve in hEATING zone LT1 0 = Disabled, 1 = Enabled
Fixed water outlet temperature set point in hEATING zone LT1
Enable compensation curve in COOLING zone LT1: 0 = Disabled, 1 = Enabled
74
PBM 20÷40 EN
U I A
U I A
Menu Parameter no. UOM
Mn00
0015
Mn00
0022
°C
Mn00
0023
°C
Mn00
0036
Mn01
0100
Mn01
0106
°C
Mn01
0107
°C
Mn01
0108
°C
Mn01
0109
°C
Mn01
010G
Mn01
010h
Mn01
011B
Mn01
011C
Mn01
011D
Mn01
011G
Mn01
011R
Mn01
011T
Mn01
011U
°C
Mn01
0128
°C
Mn01
0129
°C
Mn01
012A
Mn01
012D
Mn01
012E
%
Mn01
012F
°C
Mn01
012G
°C
Mn01
012h
°C
Mn01
012J
°C
Mn01
012L
°C
Mn01
012M
°C
Mn01
012N
Mn01
012P
%
Mn01
012R
°C
Mn01
0130
°C
Mn01
0131
°C
Mn01
0132
°C
Mn01
0133
°C
Mn01
0134
°C
Mn01
0135
°C
Mn01
0136
°C
Mn01
0137
°C
Mn01
0138
°C
Mn01
0139
°C
Mn01
0140
°C
Mn01
0141
°C
Mn01
0143
Mn01
0146
Mn01
0147
Mn01
0148
Mn01
0152
Mn01
0153
°C
Mn01
0154
Mn01
0155
°C
Mn01
0156
Mn01
0157
%
Mn01
0158
°C
Mn01
0159
Mn01
015A
Mn01
015B
Mn01
015C
Mn01
015D
Mn01
015E
Mn01
0163
Mn01
0164
%
Mn01
0165
°C
Mn01
0166
°C
Mn01
0167
Mn01
0168
Mn01
0169

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pbm-i 30Pbm-i 40

Tabla de contenido