LIST OF PARAMETERS
Description
Fixed water outlet temperature set point in COOLING zone LT1
Enable compensation for room humidity, ZONE LT1: 0= Disabled , 1= Enabled
Room relative humidity value to start increasing water outlet temperature set point, ZONE LT1
Maximum outlet temperature hysteresis corresponding to 100% relative humidity
Zone LT1 compensation curve number
Enable room temperature influence on LT1 0= Disabled 1= Enabled
LT1 Room Authority
MINIMUM outlet set point limit for compensation curve in zone LT1
MAXIMUM outlet set point limit for compensation curve in zone LT1
Enable compensation curve in hEATING zone LT2 0= Disabled 1= Enabled
Fixed water outlet temperature set point in hEATING zone LT2
Enable compensation curve in COOLING zone LT2: 0= Disabled, 1= Enabled
Fixed water outlet temperature set point in COOLING zone LT2
Enable compensation for room humidity, ZONE LT2: 0= Disabled , 1= Enabled
Room relative humidity value to start increasing water outlet temperature set point, ZONE LT2
Maximum outlet temperature hysteresis corresponding to 100% relative humidity
Zone LT2 compensation curve number
Enable room temperature influence on LT2 0= Disabled 1= Enabled
LT2 Room Authority
MINIMUM outlet set point limit for compensation curve in zone LT2
MAXIMUM outlet set point limit for compensation curve in zone LT2
Recirculating pump activation time
Electric heater operating mode: 0 = DhW production disabled, 1 = heat pump only, 2 = Electric heater only,
3 = heat pump + electric heater
Setpoint temperatura Acqua Sani taria con Resistenza
Domestic hot water temperature set point for Legionella prevention
Legionella prevention cycle day MONDAY (0=no 1=yes)
Legionella prevention cycle day TUESDAY (0=no 1=yes)
Legionella prevention cycle day WEDNESDAY (0=no 1=yes)
Legionella prevention cycle day ThURSDAY (0=no 1=yes)
Legionella prevention cycle day FRIDAY (0=no 1=yes)
Legionella prevention cycle day SATURDAY (0=no 1=yes)
Legionella prevention cycle day SUNDAY (0=no 1=yes)
Legionella prevention cycle day SUNDAY (0=no 1=yes)
Legionella prevention cycle time
Enable Legionella prevention function 0 = Not enabled 1 = Enabled
Legionella prevention function with: 0 = heat pump only 1 = electric heater only 2 = heat pump + electric heater
Minimum heat pump operating time for system
Maximum heat pump operating time to reach domestic hot water set point
Three-way valve travel time for domestic hot water production
Enable electric heater: 0 = heater not enabled, 1 = heater enabled
Enable boiler: 0 = Boiler not enabled, 1 = Boiler enabled
Activation for low outside air temperature: 0 = Function not enabled, 1 = Function enabled
Outside air temperature to enable electric heater
Activation for low outside air temperature: 0 = Function not enabled, 1 = Function enabled
Outside air temperature to enable boiler
Minimum outside air temperature for heat pump operation
(make sure the value shown in the table is set)
Electric heater activation delay time
(allows the heat pump to reach steady operation and thus avoid activating the heater when not needed)
Integration time to activate outlet electric heaters
Boiler activation delay time
(allows the heat pump to reach steady operation and thus avoid activating the boiler when not needed)
Integration time to activate boiler
Enable manual heater operation
BT1 System heat exchanger water inlet temperature probe
BT2 System heat exchanger water outlet temperature probe
BT8 Domestic hot water probe
BT7 Unit control air temperature probe
BT9 Storage tank probe
BT11 Outside air temperature probe for set point management
BP1 Condenser/evaporator control pressure transducer
BT5 Compressor suction temperature probe
BT6 Compressor discharge temperature probe
BP2 Low pressure transducer
U I A
U I A
Menu Parameter no.
UOM
Mn01
0170
°C
Mn01
0171
Mn01
0172
%
Mn01
0173
°C
Mn01
0174
Mn01
0178
Mn01
0179
%
Mn01
0180
°C
Mn01
0181
°C
Mn01
0182
Mn01
0183
Mn01
0184
Mn01
0185
°C
Mn01
0186
Mn01
0187
%
Mn01
0188
°C
Mn01
0189
Mn01
0193
Mn01
0194
%
Mn01
0195
°C
Mn01
0196
°C
Mn02
0201
min.
Mn02
0202
Mn02
0209
°C
Mn02
0211
°C
Mn02
0213
Mn02
0214
Mn02
0215
Mn02
0216
Mn02
0218
Mn02
0219
Mn02
0220
Mn02
0221
h
Mn02
0222
Mn02
0223
Mn02
0225
min.
Mn02
0226
Mn02
0227
Mn02
0231
sec.
Mn03
0300
Mn03
0301
Mn03
0303
Mn03
0304
°C
Mn03
0306
Mn03
0307
°C
Mn03
0311
°C
Mn06
0616
min.
Mn06
0617
°C*sec
Mn06
0618
min.
Mn06
0619
°C*sec
Mn06
0620
Mn09
0900
°C
Mn09
0901
°C
Mn09
0902
°C
Mn09
0903
°C
Mn09
0904
°C
Mn09
0905
°C
Mn09
0906
bar
Mn09
0909
°C
Mn09
0910
°C
Mn09
0911
bar