RECEIVING AND HANDLING THE PRODUCT

VISUAL INSPECTION

When the items are consigned by the carrier:
- make sure that the goods delivered correspond to the
description on the delivery note, comparing this against
the data on the packaging label.
- make sure the packaging and the unit are intact.
If damage or missing components are noted, indicate this on
the delivery note. A formal complaint should be sent via fax
or registered post to the After Sales Department within eight
days from the date of receipt of the items.
HANDLING PACKAGED UNITS
The unit should always be handled by qualified personnel
using equipment adequate for the weight of the unit, in com-
pliance with the safety standards in force (and subsequent
amendments).
• Lifting by forklift (1)
Insert the forks under the long side of base, opening the
forks as fare as possible.
• Lifting by crane (2)
Use slings with hooks suitable for the weight being lifted.
Secure the hook to the lifting bracket fixed to the unit, use
always equal length slings, as shown in the figure, to
ensure the weight is balanced.
Dimensioni
Dimensioni L
Dimensioni P
Dimensioni h
Peso lordo
REMOVING THE PACKAGING
The packaging must be removed by the operator using suit-
able protective equipment (gloves, glasses, etc.).
Take special care not to damage the unit. Observe the local
standards in force as regards disposal of the packaging,
using specialist collection or recycling centres.
Do not dispose of packaging materials in the environ-
ment or leave them within reach of children as they may
represent a hazard.
Envelope A, located in the compressor compartment, con-
tains:
• installation - operating - service manual;
• user manual;
• list of the main components and sub-assemblies fitted on
the product
Make sure the components listed above are not lost or mis-
placed.
The installation manual is an integral part of the unit
and should therefore be read and kept carefully.
STORING THE UNITS
The units must be stored sheltered from direct sunlight, rain,
wind or sand.
Avoid exposing the units to direct sunlight, as the pressure
inside the refrigerant circuit may reach dangerous values
and cause the activation of the safety valves, where fitted.
The units cannot be stacked.
L
PBM-i 20
mm
1530
mm
650
mm
1400
kg
230
2
Bar code
(compressor side)
H
P
1
PBM-i 30
PBM-i 40
1530
1780
650
1900
1900
300
EN PBM 20÷40
I A
750
350
A
7