STD
SLIM
ADDING A TORQUE PRESET
1. From manual target torque screen, select units of measure.
2. Press and hold UNITS button for 3 seconds.
3. ADD PRESET confirmation screen is displayed. Highlight YES menu selection using UP/DOWN
buttons then press ENTER button. NO menu selection returns to main menu without adding a PSET.
4. TARGETTORQUE screen is displayed. TARGET TORQUE is target value of fastener. Initial TARGET
TORQUE value is value from target torque screen. TARGET TORQUE can be set to any value within
wrench torque range by pressing UP/DOWN buttons. Once desired target torque value has been
set, press ENTER button.
5. MINIMUM TORQUE screen is displayed. MINIMUM TORQUE is value at which green progress
lights, audible alert and vibrator turn on. Initial MINIMUM TORQUE value is TARGET TORQUE value
minus negative torque tolerance (default 0%, see MODE SETUP in Advanced Configuration section).
MINIMUM TORQUE can be set to any value from TARGET TORQUE to wrench minimum torque range
by pressing UP/DOWN buttons. Once desired minimum torque value has been set, press ENTER button.
15