Change Password - Bahco TAWM Serie Traducción De Las Instrucciones Originales

Llave dinamométrica electrónica con lectura de par, ángulo y memoria
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 563
TAWM SERIES
2. CAL INTERVAL screen is displayed.
3. Use UP/DOWN buttons to change calibration interval.
Selectable Intervals: 12 MON (factory default); 6 MON; 3 MON; DISABLED
4. Press ENTER button to accept selection and exit to Configure menu.
STD
Note: Clock Date and Time must be set before calibration interval will function. If batteries are
removed from wrench for longer than 20 minutes, clock will revert to default settings and must
be re-entered at power on.
Note: Calibration interval is calculated from either IN-Service Date or last Calibration date (see
SHOW INFO menu) depending on which is more recent date. When clock Date is greater than
IN-Service or Last Calibration date, plus Cal Interval, "CAL NEEDED" message will be displayed
on power up and after a re-zero. Pressing ENTER button will continue to target menu. Applying
torque while "CAL NEEDED" message is displayed will immediately display torque or angle
measurement and return to target menu when released.
Note: As an alternative to calibration interval, a Calibration Cycle Counter is provided in Calibration
menu (Refer to Calibration Manual regarding Calibration menu). Each time a measurement cycle
reaches target torque, calibration cycle counter is incremented. When torque is recalibrated,
calibration counter is automatically reset to zero. User can disable calibration interval check and
use number of cycles since last calibration to decide when to recalibrate.
Note: If an invalid date is entered and Calibration interval is enabled, an unintended "CAL NEEDED"
message may be displayed. Either disable the calibration interval or enter a correct date.

CHANGE PASSWORD

Change Password function allows user to change password to a new password. Default password is
required to initially change the password (Refer to Calibration Manual for Configure password).
1. From Configure menu, use UP/DOWN buttons to highlight CHANGE PASSWD selection then press
ENTER button.
2. Initial password entry screen is displayed.
3. Enter default password if changing for first time, otherwise enter current user password using UP/
DOWN buttons to change each digit followed by ENTER button.
4. Change password entry screen is displayed.
5. Enter new password using UP/DOWN buttons to change each digit followed by ENTER button.
6. Confirm password entry screen is displayed.
7. Re-enter new password using UP/DOWN buttons to change each digit followed by ENTER button.