MSA WinGrip Latchways All In One Instrucciones Para El Usuario página 3

Tabla de contenido

Publicidad

EN
Incorrect storage may reduce the service
life of the components.
Maximum product life
Latchways WinGrip AIO service life is
determined by the device condition as
prescribed by pre-use checks and periodic
examinations; there is no fixed service life.
Continued use is dependent upon passing
pre-use checks and periodic examinations.
Service life may be reduced by frequency
and conditions of use or local regulations.
Components with a fixed maximum service
life are indicated in Table 4.
If an issue is identified, a User
has fallen on the anchor or any
doubt exists as to the suitability,
the Latchways WinGrip AIO
shall be tagged "unusable" and
withdrawn from service.
Prior to return to service MSA or a
1
Technician
shall confirm, in writing, that
Latchways WinGrip AIO has passed
examination.
WinGrip component disposal:
The stainless steel, aluminium, rubber
and plastic parts of Latchways WinGrip
AIOs are recyclable. The harness and
Energy absorber lanyards shall be cut, to
prevent accidental use, and disposed of
as domestic waste.
Product terminology
Component
EN
06 Read instructions
07
Model number
REF
08 Manufacturer
09 Vacuum anchor gauge
10 Test button
11 Alarm mute
12 Air inlet
13 Single User capacity
14 Standard
15
Serial number
SN
16 Vacuum outlet - used to install Latchways
WinGrip Flying anchor (via Primary hose)
17 Notified body number
18 Carrying handle
19 Slide valve (on / off)
20 Supply pressure indicator
21 System side vacuum gauge
22 Cylinder lock release catch
23 Rotating arm with Energy absorber
lanyard
24
Date of manufacture
25 Plastic coated D-ring
26 Filling adaptor
Production control phase
Inspec International B.V.
(Notified Body No: 2849)
Beechavenue 54, 1119 PW,
Schiphol - Rijk, Netherlands
Notified bodies
SATRA Technology Europe Limited
(Notified Body No: 2777)
Bracetown Business Park
Clonee, D15YN2P
Republic of Ireland
Authorised representative
MSA Europe GmbH
Schlusselstrasse 12, Rappersvil-Jona
8645, Switzerland
4
Table 1:
Pre-use examination
Item
Function
Latchways
Single point vacuum anchor.
WinGrip AIO
Provides connection between the
REF 80000-03
vacuum anchor and the User via a
Energy absorber
Work positioning rope.
Latchways
Used as a single point vacuum
WinGrip Flying
anchor during installation, or when
vacuum anchor
working on an area that cannot
be accessed from the Latchways
WinGrip AIO. The flying anchor may
carry a spare Latchways WinGrip
cylinder
.
01
Provides up to 6 hours use for a
01
single installation. Set to deliver
Latchways
compressed air at 115 psi. May be
WinGrip Cylinder
filled by a Competent person (
filling adapter may be required). Has
an in-built pressure release valve
and safety burst disk (6500 psi).
Flexible re-enforced rubber tubing
02
with a male and a female connector.
Primary
vacuum hose
When used in combination with the
03
Energy absorber the harness can
Latchways
sustain the forces developed during
WinGrip harness
a fall.
Used to secure the User to the
04
05
anchor point. Double ropes have the
Work positioning
advantage of attaching to two points
ropes
and are therefore required during
installation to provide 100% tie-off.
Pre-use checks
Ensure that the seal is clean and
intact.
Ensure that Energy absorber is
within date and that there is no
evidence of excessive wear.
Ensure that the seal is clean and
intact. Ensure the energy absorber
is undamaged and within service
life.
Ensure the cyclinder is filled, holding
the charge and within current
hydrostatic test.
26
Ensure that the hose is intact and
that the connector operates.
Examine in accordance with
manufacturer's instructions. Ensure
the Latchways WinGrip harness is
within date.
Ensure that all Work positioning
ropes are intact and that the
connectors operate correctly. Ensure
the Latchways WinGrip harness is
within date.