4.6 Correction values in the case of divergent operating conditions

4.6.1
Mean boiler water temperature
Differential exhaust gas
temperature
Air excess
Differential exhaust gas
temperature
4.6.2
Mean temperature difference*
Correction for stopped losses
* Mean temperature difference = mean boiler water temperature minus ambient air temperature
Mean boiler water temperature = mean value of outlet and return temperature
1NO0P0007-A
Varjet 1 - 14
Exhaust gas temperature correction values
t °C
t K
-
t
K
Correction values for losses when stopped in the case of divergent operating
conditions
tm
qB
-
40
50
60
-24
-16
-8
-
1.10
1.15
1.20
-4
-2
± 0
-
°C
30
40
%
-40
-20
70
80
90
± 0
+8
+16
1.25
1.30
1.35
+2
+4
+5
50
60
70
± 0
20
40
84