8
Troubleshooting
8020356.1DS8/2021-11-24 | SICK
Subject to change without notice
Reflector PL40A
5
Reflector C110
6
Reflector PL80A
7
Operating reserve
100
WLD26P-xxxxx1xx
3
4
10
2
1
1
0
4
8
12
(13.12)
(26.25)
(39.37)
Distance in m (feet)
Figure 13: Characteristic line 2
Reflector PL20 CHEM
1
Reflector P250 CHEM
2
Reflector P250H
3
Reflector PL40 Antifog
4
Operating reserve
100
WLD26P-xxxxx1xx
10
1
0
2
4
6
(6.56)
(13.12)
(19.69)
Distance in m (feet)
Figure 15: Characteristic line 3
REF-IRF (50x70 mm)
1
The Troubleshooting table indicates measures to be taken if the sensor stops working.
LED/fault pattern
Switching outputs do not
behave in accordance with
table 3
1
0.25
2
0.25
3
0.25
4
0.25
0
(13.12)
Sensing range
Sensing range
16
20
(52.49)
(65.62)
1
0.3
0
(6.56)
Sensing range
Sensing range
8
10
(26.25)
(32.81)
Cause
1. Change of the configuration
2. Short-circuit
O P E R A T I N G I N S T R U C T I O N S | WLD26
TROUBLESHOOTING
4
6
7
10
10
12
10
14
4
8
12
16
(26.25)
(39.37)
(52.49)
Distance in m (feet)
Sensing range max.
Figure 14: Bar graph 2
3
5
2
4
6
8
(13.12)
(19.69)
(26.25)
Distance in m (feet)
Sensing range max.
Figure 16: Bar graph 3
Measures
1. Adjustment of the configura‐
tion
2. Check electrical connections
8
20
(65.62)
en
10
(32.81)
21