RESET: To reset after shutdown occurs, remove the 12-volt
plug from the accessory outlet. Check the source of the problem
and correct. Reinsert the 12-volt plug into the accessory outlet.
8.

If THE INVERTER fUSE bLOWS

Your power inverter is fitted with a fuse, which should not have
to be replaced under normal operating conditions. A blown fuse
is usually caused by reverse polarity or a short circuit within the
device or equipment being operated.
If the fuse does blow:
1.
Disconnect the device or equipment immediately.
2.
Find the source of the problem, and repair it.
3.
Install a new fuse, (10-amp for Model PI-70 and 15-amp
for Models PI-120 and PI-140). The fuse can be found on
the end of the plug on the inverter.
4.
Do not tighten the fuse cap too tight; finger tight is suf-
ficient.
ATTENTION: Do not install a fuse higher than 10-amp for
Model PI-70, and 15-amp for Models PI-120, PI-140, as this
may damage the inverter. Make sure to correct the cause of the
blown fuse before using the inverter again.