If THE INVERTER fUSE bLOWS

Your power inverter is fitted with a fuse, which should
not have to be replaced under normal operating condi-
tions. A blown fuse is usually caused by reverse polarity
or a short circuit within the device or equipment being
operated.
If the fuse does blow:
1. Disconnect the device or equipment immediately.
2. Find the source of the problem, and repair it.
3. Install a new fuse, (25-amp for Models PI-200 and
PI-400 and 45-amp for Model PI-750). The fuse can
be found on the right side of the inverter.
Attention: Do not install a fuse higher than 25-amp for
Models PI-200 and PI-400 and 45-amp for Model PI-750,
as this may damage the inverter and any product you
use with the inverter. Make sure to correct the cause of
the blown fuse before using the inverter again.