If The Inverter Fuse Blows - Schumacher Electric PI-200 Manual Del Usuario

Convertidor de energía
Ocultar thumbs Ver también para PI-200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

RESET: To reset after shutdown occurs:
1.
Disconnect the inverter from the 12V power source.
2.
Check the source of the problem and correct.
3.
Reconnect the inverter to the 12V power source.
NOTE: If the red LED is lit and the green LED is not, see the
Troubleshooting section.
8.

IF THE INVERTER FUSE BLOWS

Your power inverter is fitted with a fuse, which should not have
to be replaced under normal operating conditions. A blown fuse
is usually caused by reverse polarity or a short circuit within the
device or equipment being operated.
If the fuse does blow:
1.
Disconnect the device or equipment immediately.
2.
Find the source of the problem and repair it.
3.
Install a new fuse (25-amp for Models PI-200, PI-400 and
XI41B; 45-amp for Model PI-750). The fuse can be found on
the right side of the inverter. NOTE: If you are using the 12V
accessory plug to power the inverter, there is also a 15-amp
fuse in the end of the plug.
the original fuse, as this may damage the inverter and any product
you use with the inverter. Make sure to correct the cause of the
blown fuse before using the inverter again.
Do not install a fuse with a higher amp rating than
• 9 •

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pi-400Pi-750Xi41b

Tabla de contenido