Repairs at the unit
11.6

Replacing the Transducer

1. Open the relief valve, valve position PRIME (k circulation),
switch the unit OFF, and unplug the power cord.
2. Loosen and remove the four motor shroud screws (Fig. 19,
item 1). Remove the motor shroud (2).
3. At the electronic control assembly (3), disconnect the black
wire coming from the transducer (4).
4. Pull the grommet (5) out of the mounting plate (6) and slide
it up the shaft of the transducer (4) until it is clear of the
mounting plate (6).
3
6
5
4
9
5. Using a wrench, loosen and remove the transducer (4) from
the filter housing (7). Carefully thread the transducer wire out
through the mounting plate (6). Replace the transducer cap
(8) and inner seal (9), if damaged.
6. Slide the grommet (5) off of the old transducer and onto the
new transducer.
7. Thread the new transducer wire through the mounting plate
(6) and up to the electronic control assembly (3).
8. Thread the new transducer (4) into the filter housing (7) and
tighten securely with a wrench.
i
Make sure the transducer cap and inner seal on
the transducer are in place before threading the
transducer into the filter housing.
9. Push the grommet (5) into the mounting plate (6).
10. Connect the transducer wire to the electronic control
assembly (refer to the electrical schematic in Section 11.7 of
this manual).
11. Slide the motor shroud (2) over the motor.
12. Secure the motor shroud (2) with the four motor shroud
screws (1).
1
2
7
8
GB
18
Performance Series 850e

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Performance 0558071Performance 0558077

Tabla de contenido