Beninca VN.M20E Manual Del Usuario página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
• Before installing the automatic system read the instructions
hereunder carefully.
• It is strictly forbidden to use the product VN.M for applications
other than indicated in this instruction handbook.
• Show the user how to use the automation system.
• Give the user the part of the leaflet which contains the instructions
for users.
• All Benincá products are covered by an insurance policy for any
possible damages to objects and persons caused by construc-
tion faults, under condition that the entire system be marked CE
and only Benincá parts be used.
OPERATiNg LiMiTS AND WARNiNgS
This geared motor has been studied and manufactured to activate
balanced sectional doors (VN.M20E/VN.MT20E) as well as rolling
doors (VN.M40E/VN.MT40E). Before proceeding to install the sys-
tem, make sure that the door is balanced and slides well. Check
that the ropes, the springs and the parachuting system are in good
conditions. For doors that have not been installed recently, check
also all the other parts subject to wear and tear. The above instruc-
tions are essential for the safety of the system and the reliability
of the operator.
iNSTALLATiON
Thanks to its versatility, this geared motor can be assembled not
only on the right-side or left-side of the door, but also horizontally
(fig. 2) or vertically (fig. 3). The geared motor has been designed
to directly activate the cable winding shaft of the door which must
feature 1" diameter (25.4mm) and should be provided of housing
for the key. For cable winding shafts having a different diameter,
an adapter should be provided (item VN.A30 for diam. 30 shafts,
item VN.A3175 for diam. 31.75 shafts, item VN.A40 for diam. 40
shafts). To fit the unit proceed as follows (fig.4):
• Check that the distance between the rope coiler shaft "A" and
the surface onto which brackets should be fitted ranges between
82 and 150mm.
• Weld or fit the bracket "S" to surface with screws.
• Introduce the gear motor in the rope coiler shaft, while interposing
the key "C".
• Tighten the fitting screws "V".
• To mount the plate on side "B", use screws TE M10x20 sup-
plied.
To calculate the movement speed of the door, proceed as fol-
lows:
V = d (diam. of cable winding drum - m) x 3.14 x 24 = m/1'
It is possible to use the geared motor by extending the motion to
the rope winding-up shaft by means of a chain (item VN.RM). The
motion can possibly be transmitted reduced or multiplied (item
VN.RV) (fig. 5).
To calculate the movement speed of the door, proceed as fol-
lows:
V = d (diam. of cable winding drum - m) x 3.14 x 24 x Z1 / Z2 = m/1'
WiRiNg (fig. 6)
VN.MT20E / VN.MT40E
Earth.
GND
Not used.
Open limit switch 1x0.5 min.
SWO
SWC
Close limit switch 1x0.5 min.
COM AUX
Common of the contact at disposal
Not used.
3A, 24Vdc/ac max.
AUX
L1
L1/M
L2
L2/COM
L3
L3/M
Not used.
COM SW
Common of Limit switch 1x0.5 min. Common of Limit switch 1x0.5 min.
---
Not used.
12
WARNiNg
VN.M20E / VN.M40E
Earth.
Not used.
Open limit switch 1x0.5 min.
Close limit switch 1x0.5 min.
Common of the contact at disposal
Not used.
3A, 24Vdc max.
Phase
Com.
Phase
Not used.
Not used.
VN.M20E/VN.M40E: The 25µF capacitor must be connected to the
motor terminals 7 and 8 of THINK control unit.
To use the micro-switch supplied as a safety limit switch in the
closing phase, modify the cable positions as per fig. 7.
N.B.: Models 400V three-phase can be used also at 230V three-
phase by changing from a star connection to a triangle one as per
fig. 8.
ADjuSTMENT OF THE LiMiT SWiTCHES
The geared motor is equipped with 4 microswitches:
Red limit switch
Opening limit switch (SWO)
Blue limit switch
Opening over-travel (SWO XT)
Yellow limit switch
Closing limit switch (SWC)
Black limit switch
At disposal of the accessories (AUX)
To adjust the cams proceed as follows:
• Manually move the door until it is almost closed and adjust the
SWC cam until the micro-switch is almost triggered (Fig. 9).
• Tighten the dowel shown in Figure 10 by using a 2.5mm socket
head key.
• By using the same key, carry out the micrometric adjustment of
the cam, as shown in Figure 11.
• Repeat the operation while opening the door and adjust the SWO
cam.
• Then position the SWO XT cam so that it is activated slightly
delayed with respect to the SWO cam.
• Power the automatic unit and operate it (if it is a closing operation,
invert wires 1 and 3 of the motor power supply, fig. 6 and 7).
• Should further adjustments be required, turn the micrometric
adjustment dowel.
Figure 12 shows the wire diagram of limit switches in single-phase
motors, while Figure 13 shown wire connections in three-phase
motors.
Technical data
VN.M20E
Power supply
1x230V (50Hz)
Consumption
3A
Power
600W
Torque
90Nm
3700N
* Door max. weight
25.4mm
Exit shaft hole
1500N
Max. force on Ø 120
Exit rounds
24rpm
** L.S. reduction ratio
1/20
Jogging
40%
Thermal switch trig.
130°C
Operat. temperature
-20°C / +70°C
20µF
Capacitor
Agip Blasia 32
Lubrication
15kg
Weight
Dimensions: see fig.1
* For balancing doors and diameter Ø 120mm of the steel cable winding drum.
** Max. no. of rounds from the exit shaft.
VN.MT20E
VN.M40E
VN.MT40E
3x400V (50Hz)
1x230V (50Hz)
3x400V (50Hz)
1.7A
3A
800W
600W
105Nm
90Nm
4800N
3700N
25.4mm
25.4mm
1750N
1500N
24rpm
24rpm
1/20
1/40
50%
40%
130°C
130°C
-20°C / +70°C
-20°C / +70°C
-20°C / +70°C
20µF
Agip Blasia 32
Agip Blasia 32
Agip Blasia 32
15kg
15kg
1.7A
800W
105Nm
4800N
25.4mm
1750N
24rpm
1/40
50%
130°C
15kg

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vn.m40eVn.mt20eVn.mt40e

Tabla de contenido