Dea LIVI 400 Instrucciones De Uso página 13

Ocultar thumbs Ver también para LIVI 400:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

"EXAMPLE OF TYPICAL INSTALLATION" picture
Type of control
Person-present control
Pulse control with the gate in
sight
Pulse control with the gate
not in sight
Automatic control
(i.e. control with
timed closing)
Remember that anyone who sells and/or motorises doors/gates becomes the manufacturer of the automatic door/gate
machine and must therefore prepare and conserve a technical folder that contains the following documents (see Machinery
Directive Enclosure V):
• Assembly drawing of the automatic door/gate;
• Electrical connection and control circuit wiring diagram;
• Risk analysis including: a list of the essential safety requirements provided in Machinery Directive Enclosure I; a list of the risks
posed by the door/gate and the description of the solutions adopted.
• Keep these operating instructions in a safe place together with the instructions for all the other components;
• Prepare these operating instructions and general safety warnings (for the completion of these operating instructions) and
deliver a copy to the final user;
• Fill out the maintenance register and deliver a copy to the final user;
• Draft the CE declaration of conformity and deliver a copy to the final user;
• Fill out the complete CE label or plate and apply it to the door/gate.
Note: The technical folder must be conserved for inspection by the competent national authorities for at least ten years from
the date construction of the automatic door/gate.
Operating instructions and warnings
1
2
3
4
"OPERATING CONTROL" table
Informed users
(private areas)
Pushbutton control
Force limitation
or
presence detectors
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
RESPONSIBILITIES OF THE INSTALLER
5
6
7
Type of use
Informed users
(public areas)
Pushbutton control with key
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
L I V I
Pos.
Description
1
1Pilly 60 column
2
LIVI
3
104 Lux series
photocells
4
Safety edge
5
Lumy flashing light
6
Remote-control
7
102 Lux key selector
Uninformed users
The person-present control is
not possible
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
11

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido