7-6-5
Replacing the Trigger Switch
1.
Remove the gun cover and gun slide (R).
7-6-3 page 63)
2.
Replace the microswitch. Take care when replacing the switch that
the correct wires are fitted to the correct terminals.
3.
Reassemble in reverse order.
7-6-6
Replacing the Flexible Gun Conduit.
1.
Remove the gun assembly.
2.
Remove the 2off security screws (M4x10), then detach the connector
cover.
3.
Remove the gun cover and gun slide (R).
7-6-3 page 63).
4.
Detach the solenoid bracket and detach the solenoid connectors and
earth wire.
5.
Disconnect the sensor and detach the fast-on connectors from the
micro switch.
6.
Remove the button head screw (M4x10) fixing the conduit to the gun
cover (L) and detach the conduit.
7.
Reassemble in reverse order.
(See 7-6-1- page 61).
(see 7-6-4 page
64).
Page 65
(See 7-6-2 page 62
(See 7-6-2 page 62
and
and