POINT A -
ELECTRIC CONNECTIONS
B
J19
J2
J3
J4
J5
J1
N F
Power supply 230 Vac 50/60 Hz - external to the control
panel - (120 V 60 Hz upon request)
J2
A+COM
+ 24Vdc accessories power supply
A-
- 24Vdc accessories power supply
A+TEST
+ 24Vdc Photocells self-test power supply
J3
OPEN
Open pulse contact (NO)
CLOSE
Close pulse contact (NO)
START
Single pulse contact (NO)
PED.
Pedestrian opening pulse contact (NO)
B.I.O.
Clock contact (NO)
COM A+
Contacts common / Positive 24 Vdc
J4
COM A+
Contacts common / Positive 24 Vdc
STOP
Stop pulse contact (nc)
PHOT 1
Photocells 1 contact (nc)
PHOT 2
Photocells 2 contact (nc)
EDGE 1
Edge 1 contact (nc)
EDGE 2
Edge 2 contact (nc)
J5
Radio Antenna 433MHz
J6
RADIO
Connector for radio module ACG8069
J7
BATTERY CHARGER
Connector for battery charger board (code ACG4776 optional)
(24V DC SOLAR)
J8
BATTERY +/-
Battery connectors (optional)
J9
10VAC
Connectors for secondary 10 Vac transformer
J10 24VAC
Connectors for secondary 24 Vac transformer
B – SETTINGS
DIP 1
adjust stroke in line with electrical or magnetic limit switches (point C)
DIP 2
programme full opening (point D)
DIP 2-1
programme pedestrian opening times (point E)
DIP 1-2
save/delete radio codes for full opening control (point F)
DIP 1-3
save/delete radio codes for pedestrian opening control (point G)
DIP 1-2-3 save/delete radio codes for relay R-AUX command (point H)
DIP SWITCHES CONTROL
DIP 4
Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5
Pre-blinking (ON) - Normal blinking (OFF)
DIP 6
Single pulse command (START) and RADIO - step-by-step (ON) - automatic (OFF)
DIP 7
Photocells AUTO-TEST activation (ON-activated).
DIP 8
Available
DIP 9
Available
DIP 10
Gradual brake (ON-activated)
DIP 11
Gradual start (ON - activated)
DIP 12
Activate the radio system SUN/MOON (ON) - SUN-PRO (OFF)
DIP 13
Heater (ON - activated)
J15
J17
J16
J13 J12
J6
J7
J8
J11 SERIAL COM / SYNC Connector for serial connection
J12 SECURITY LOCK
J13 LIMIT SWITCH
J14 MOTOR
J15 X K800
J16 APP
J17 APP+
J18
J19 R-AUX
F1
F2
DIP 14
DIP 15
OFF
ADJUSTMENTS
RUN TRIMMER - high-speed regulator
With this trimmer it is possible to adjust the motor speed (set as standard to the max speed).
The adjustment is quite useful to align the automation with the European standards on
impacts.
For gates weighing from 0 to 200 kg is recommended to set the RUN trimmer from
1/2 to MAX.
For gates weighing from 200 to 400 kg is recommended to set the RUN trimmer from
MIN to 1/2.
LOW SP TRIMMER - slow speed approach regulator
The slow speed control is performed by adjusting the LOW SP trimmer which changes the
32
J14
PROG
J11
J1
F2
F
N
F1
J9
Connector for manual release switch
Connector for electrical or magnetic limit switches
Connector for 24 Vdc motor and 5 Vdc encoder
Connectors for motor K800 connection (do not use)
Connector for APP Card
Connector for APP+ Card
RS485 termination of J17
Auxiliary relay contact (NO) Max 700 W
SIGNAL -
Open gate indicator 24 Vdc max 3 W
COM A+
Contacts common / Positive 24 Vdc
Negative flasher 24 Vdc 20 W (code ACG7061)
SENS
Trimmer for adjusting sensitivity to impact against an obstacle
TCA
Trimmer for automatic closing time adjustment (DISABLED
DEFAULT AND DL11 LED OFF)
RUN
Trimmer for high speed adjustment operations
LOW SP
Trimmer for low speed adjustment operations
PROG
Programming key
T 1,6 A
Transformer protection fuse (external to the card L1 24V)
T 10 A
Motor protection fuse
Available
DIP 16
OFF
K400
F
> PHASE
N
> NEUTRAL
> EARTH