RIB K400 L1 24V-CRX Manual Del Usuario página 33

Ocultar thumbs Ver también para K400 L1 24V-CRX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

voltage output across the motor(s) (turning it clockwise increases the speed).
Adjustment is performed to determine the correct speed at the end of opening and closing
according to the gate or when there is friction that might cause the system to function poorly.
TCA TRIMMER - AUTOMATIC CLOSING pause time regulator for TOTAL or PEDESTRIAN
openings
default NOT ACTIVATED and LED DL11 OFF
(trimmer fully rotated counterclockwise)
This trimmer makes it possible to adjust the pause time for total or pedestrian automatic
closing. Only with gate completely open (total) or partially open (pedestrian) and LED DL11
ON (trimmer rotated clockwise to activate the feauture).
The pause time (for a totally opened gate) can be adjusted from a minimum of 2 s up to a
maximum of 2 minutes.
The pause time (for gate open with PED. control) can be adjusted from a minimum of 2
seconds to a maximum of 30 seconds.
Ex: With TCA trimmer setted halfway, you will have 1 minute pause after the total opening and
15 seconds of pause after the pedestrian opening prior to have the auto-close of the gate.
TRIMMER SENS - impact sensor regulator
Default enabled and DL15 ON (trimmer halfway)
The L1 24V control board is equipped with an impact sensor that reverses the gate's travel if
it impacts on things or people (in compliance with the EN standards in force - always check
with a suitable instrument to comply with the values set by the EN12453 standard.
With impact in opening, it reverses the closing movement for 1 second and then stops.
With impact on closing, it reverses the opening movement for 1 second and then stops.
With this trimmer it is possible to adjust the impact reaction:
- with trimmer turned fully counter-clockwise and DL15 OFF, impact sensor deactivated.
- with trimmer at minimum, the impact reaction occurs after 3 seconds (low sensitivity)
- with trimmer at halfway, the impact reaction occurs after 1.5 seconds (medium sensitivity)
- with trimmer at max, the impact reaction occurs after 0,4 seconds (high sensitivity)
The movement will restart at a slow speed until the opening or closing limit switch is reached.
IMPACT SENSOR ALARM
The alarm status will be displayed by the flasher which will remain active for one minute and
the buzzer with 3 tones every 5 seconds. During this time, the gate can be reset by pressing
any control button.
R-AUX - AUXILIARY RELAY CONTACT (NO)
Normally this relay is set as courtesy light (max 700 W - 3 A - 230 Vac) to operate 3 minutes
at each command, with time renewed at each command.
You can activate the R-AUX contact by TRANSMITTER by performing the memorization
procedure described in point H and the RIB GATE App.
GRADUAL BRAKING
If DIp 10 ON Brake activated. With the RIB GATE app it is possible to regulate braking making
it gradual.
GRADUAL START
If DIP 3 is ON, gradual motion is enabled for 0,5 second with every start.
LED SIGNALS
DL1
programming signal enabled
DL2
opening gate signal
DL3
closing gate signal
DL4
opening limit switch signal
DL5
closing limit switch signal
DL6
STOP contact signal
DL7
photocell PHOTO 1 contact signal
DL8
photocell PHOTO 2 contact signal
DL9
EDGE 1 contact signal
DL10
EDGE 2 contact signal
DL11
TCA - automatic closure time enabled
DL12
Remotes programming enabled
DL13
Card managed by APP
DL14
encoder status signal
DL15
SENS - impact sensor enabled
DL16
manual unlock micro-switch signal
DL17
PROG commands
OPEN
OPEN command (NO)
CLOSE
CLOSE command (NO)
START
Single impulse command (NO)
PED.
Pedestrian command (NO)
B.I.O
C – LIMIT SWITCH CAMS and SPEEDS ADJUSTMENTS
This control has the task of facilitating system commissioning or any subsequent adjustments
for the installer.
N.B. : During this control the safety functions Safety edge, Photocells, Stop button and Impact
sensor are NOT active.
1 - Unlock the operator using the manual release and position the limit switch cams on the
rack, so as to define the gate stroke.
2 - Bring the gate to mid-stroke position and lock the operator.
3 - Set DIP 1 to ON mode = > led DL1 starts flashing.
4 - Press and hold the PROG button (the command is operator-run, open-stop-close-stop-
open-etc...) = > the gate starts at high speed and then slows down until it reaches the
limit stop. Check that the gate stops in the desired position. If not, move the limit switch
cams and try again. Check the limit switch on the opposite side.
5 - You can adjust the high speed during the first 5 seconds of operation by rotating the RUN
trimmer. Rotating the RUN trimmer clockwise, the speed increases. The RUN trimmer is
normally set to max.
6 - It is possible to adjust the slow speed after the first 5 seconds from the start and for
the rest of the run by operating on the LOW SP trimmer. Turning the LOW SP trimmer
clockwise increases the speed. The LOW SP trimmer is factory set at half stroke.
7 - When done, reset DIP 1 to OFF. Led DL1 goes off signalling exit from the control.
IMPORTANT: During this operation, the stop button, edges and photocells are not
enabled.
D – FULL OPENING PROGRAMMING
NB. : During the programming phase, the safety functions Safety edge, Photocells,
Stop button and Impact sensor are active and their performance level is PL "b"
according to EN13849-1. Their intervention stops the programming (led DL1
shifts from flashing to on steady).
Caution: If the inputs STOP, PHOT 1, PHOT 2, EDGE 1 and EDGE 2 are not
connected,
1/PHOT 2/EDGE 1/EDGE 2 before you proceed with programming.
N.B. : In this case, the safety functions Safety edge, Photocells, Stop button
are NOT active.
1 - IMPORTANT: TO PROPERLY PROGRAMME THE OPENING, YOU MUST POSITION THE
2 - Set DIP 2 to ON mode = > led DL1 starts flashing.
3 - Press the PROG button or the remote control button (if previously memorized) dedicated
to the total opening. The gate will begin a series of movements. DO NOT PASS IN FRONT
OF THE PHOTOCELLS WHILE THE GATE IS MOVING.
4 - The programming stops when the gate is closed and led DL1 is off.
5 - Set DIP 2 to OFF.
Note well: If at the end of the programming procedure the trimmer RUN is moved, the
Note: the low speed starting point is calculated automatically by the control unit during the
time programmin procedure. It will start 50 ÷ 60 cm before reaching the opening or
closing limit stop.
To repeat the programming procedure, position the DIP 2 in the OFF mode, and
by using the procedure "C – Adjust stroke in line with electrical or magnetic limit
switches" close the gate almost completely, leaving it open for 20 cm. Then, repeat
(red)
the programming procedure as described above.
(green)
(red)
E – PEDESTRIAN OPENING PROGRAMMING
(green)
NB. : During the programming phase, the safety functions Safety edge, Photocells,
(red)
Stop button and Impact sensor are active and their performance level is PL "b"
(red)
according to EN13849-1. Their intervention stops the programming (led DL1
(red)
shifts from flashing to on steady).
(red)
When the gate is closed:
(red)
1 - First, set DIP 2 to ON and then DIP 1 to ON. Led DL1 starts flashing.
(red)
2 - Press the pedestrian button (COM A+/PED.) or the remote control button (if previously
(red)
memorized) dedicated to the pedestrian opening = > The gate opens.
(bicolour)
3 - Press the pedestrian button to stop the gate (the pedestrian opening stroke of the gate is
(blu)
now set). After 2 seconds the gate will automatically close..
(red)
4 - When done programming the pedestrian opening, set DIP 1 and 2 to OFF.
(red)
To repeat the programming procedure, position DIP 1 and DIP 2 to OFF and by using
(red)
the procedure "C – Adjust stroke in line with electrical or magnetic limit switches"
(green)
close the gate completely. Then, repeat the programming procedure as described
(green)
above.
(green)
(green)
F - RADIO CODES PROGRAMMING PROCEDURE FOR TOTAL OPENING
(green)
33
Clock command (NO)
run
jumpers
between
GATE AT ABOUT 20 CM FROM THE CLOSING LIMIT-SWITCH.
programming procedure must be repeated.
G
B
(green)
COM
A+/STOP/PHOT

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aa40928Aa40929

Tabla de contenido