- All inputs must be used as clean contacts because the power is generated internally (secure
power) to the board and is set up to ensure compliance with double or reinforced insulation
with regard to dangerous voltage.
- Any external circuits connected to the outputs of the control panel must be made in such
a manner as to ensure compliance with double or reinforced insulation with regard to
dangerous voltage.
- All inputs are controlled by a programmed integrated circuit that performs a self check every
time it starts operating.
EVENT
Dip 1 ON (hold-to-run mode)
Or failure of a safety device
Dip 2 ON (full stroke programming)
Dip 2>1 ON (pedestrian stroke programming)
Programming sequence stopped due to intervention of a safety
device
EVENT
No transmitter code entered
Dip 1 > 2 - transmitter code programming for full opening
Dip 1 > 3 - transmitter code programming for pedestrian
opening
Dip 1>2> 3 - transmitter code programming for R-AUX relay
Correct transmitter codes programming for full opening and
R-AUX relay
Correct transmitter code programming for pedestrian opening
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for full opening, pedestrian opening, R-AUX
relay
EVENT
Stop button pressed
Photocell intervention
Edge intervention
Intervention of impact sensor
Failure of a safety device or safety device engaged for too long
Operation with emergency batteries (24 vdc)
Emergency batteries low signal
Operation with emergency batteries charged by solar panels
Alarm from edge
Impact sensor alarm
Failed photocells auto-test alarm
Encoder failure alarm
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
BUZZER STATUS
Off
Off
Off
10 seconds tone with 2 seconds pause
BUZZER STATUS
Off
Off
Off
Off
1 Tone
1 Tone
Off
Off
2 Tones
WARNING SIGNALS DURING OPERATION
BUZZER STATUS
Off
1 Tone
2 Tones
3 Tones
Off
Off
1 Tone every 5 seconds for 1 minute
(It is renewed by giving a command)
Off
2 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
3 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
4 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
5 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Off
6 Tones every 5 seconds
(It is renewed by giving a command)
Off
36
FLASHER STATUS
Off
Flashes on-off 250 ms
Off
Flashes on-off 500 ms
Off
Flashes on-off 500 ms
Off
On steady
FLASHER STATUS
DL10 LED STATUS
Off
Flashes intermittently red/green
Off
Flashes red for 10 seconds
Off
Flashes green for 10 seconds
Off
Flashes orange for 10 seconds
Off
Turns green once
Off
Turns red once
Off
Red flash
Off
Runs 6 green flashes
Off
Runs 2 green flashes
FLASHER STATUS
LED STATUS AND SIGNAL OUTPUT
Off
Led DL6 turns off
Off
Led DL7-8 turns off
Off
Led DL9-10 turns off
Off
No led combined
Off
Led DL1 flashes on-off 250 ms
Currently enabled
Signal output flashes on-off twice for 250 ms
followed by a pause of 2 seconds
Off
Signal output flashes continuously on-off for 500
ms
Off
Signal output flashes on-off 3 times for 250 ms
followed by a pause of 2 seconds
Enabled for 1 minute No led combined
Enabled for 1 minute No led combined
Off
No led combined
Off
Led DL14 off
Off
Led DL12 is steady on green.
Off
No leds matched
Off
Blue led flashes once every 5 seconds
DL1 LED STATUS