Electrical Grounding Instructions; Scope Of Use - Stanley D 200/10/24V Manual De Instrucciones

Ocultar thumbs Ver también para D 200/10/24V:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
with water-based detergents only, etc.).
● Never
exceed
the
G
recommended by the manufacturer of any attachment or
B
accessory you use with this compressor.
2. FEATURES (Pics. 1-2)
A. I/O Switch: The I/O switch is the activation
mechanism that is used to start and stop the
compressor. When the switch is "On", the motor and
pump will compress air until tank pressure reaches
the upper limit of the factory set operating pressure.
When tank pressure falls below the factory set "cut
in" pressure, the compressor will again automatically
start to compress air.
B. Handle for lifting/moving.
C. Regulated Pressure Gauge: The regulated
pressure gauge indicates the amount of pressure
that is allowed into the discharge line according to
the setting of the regulator.
D. Pressure Regulator Knob: The regulator knob
is used to adjust the air pressure that is available
at the discharge line. The discharge air pressure
is increased by turning the knob clockwise and
decreased by turning the knob counter clockwise.
E. Drain Valve: Ball style valve that drains moisture
from the tank when opened.
F.
Quick Coupler: The quick coupler is used to connect
the airline to your tool.
G. Safety valve: The safety valve is set to avoid over-
pressurization of the air tanks. This valve is factory
pre-set at 10 bar (145 PSI) and will not function
unless tank pressure reaches this pressure. Do not
attempt to adjust or eliminate this safety device.
Any adjustments to this valve could cause
serious injury. If this device requires service or
maintenance, see an Authorized Service Center.

3. SCOPE OF USE

The compressor is designed for generating compressed
air for tools operated by compressed air.
Please note that our equipment has not been designed
for use in commercial, trade or industrial applications.
Our warranty will be voided if the machine is used in
commercial, trade or industrial businesses or for equivalent
purposes.
The machine is to be used only for its prescribed purpose.
Any other use is deemed to be a case of misuse. The user/
operator and not the manufacturer will be liable for any
damage or injuries of any kind caused as a result of this.
maximum
allowable
pressure
● Please check that the air consumption and the maximum
working pressure of the pneumatic tool and connection
pipes (with the compressor) to be used, are compatible
with the pressure set on the pressure regulator and with the
amount of air supplied by the compressor.
4. ELECTRICAL GROUNDING
INSTRUCTIONS
This product should be electrically grounded. In the event
of an electrical short circuit, grounding reduces the risk of
electrical shock by providing an escape wire for electrical
current. This product is equipped with a cord having
a grounding wire with an appropriate grounding plug.
The plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
4.1 Connection of the mains plug
Important!
The wires in the mains lead fitted to this product are
coloured in accordance with the code shown in pic. 5.
● The 3 pin plug must comply to BS1363/A.
● Fuse must comply to BS1362.
If for any reason the 13 amp plug fitted to this product
requires replacement it must be wired in accordance with
the following instruction:
Do not connect the brown (live) or blue (neutral) to the
earth pin marked 'E'
Connect the Blue wire to the terminal marked Neutral (N).
Connect the Brown wire to the terminal marked Live (L).
Connect the Yellow & Green wire to the terminal marked
Earth (E). Ensure that the outer insulation is gripped by the
cord grip and that the wires are not trapped when replacing
the plug cover. The mains lead on this product is fitted with
a 13 amp (BS1363/A) plug. A 13 amp (BS1362) fuse must
be fitted in the plug.
If in doubt consult a qualified electrician
There are no user serviceable parts inside this product
except those referred to in the manual. Always refer
servicing to qualified service personnel. Never remove
any part of the casing unless qualified to do so; this unit
contains dangerous voltages.
Warning!
For your protection if this product is to be used outdoors it
should not be exposed to rain or used in damp locations. Do
not place the product on damp surfaces, use a workbench
if available. For added protection use a suitable residual
current device (R.C.D.) at the socket outlet.
Note: If the mains cable requires replacing it must be
replaced with an identical one and fitted by a
qualified person.
18
on the 3 pin plug.

Publicidad

Tabla de contenido
loading

Tabla de contenido