5.04 Fault Indicator
At initial power up, two lights will temporarily illuminate for 2-3 seconds to show the version of software
used.
To determine the first digit, count the function indicators left to right, 1 through 5. To determine the
second digit count the pressure indicators, reading from bottom to top, 0 through 7. In the example
below the Temp indicator and 75 psi indicators are ON indicating the version would be 2.3.
!
When the "Fault" indicator is ON or blinking it will be accompanied by one of the pressure indicator lights
depending on what the Fault is. The following table explains each of those Faults.
NOTE!
Fault explanations are covered in the following tables.
300x5395
7
6
5
A
MIN
MAX
PSI
BAR
MAX
MAX
4
3
2
1
MIN
MIN
0
!
1 2 3 4
5
Pressure
Fault
Indicator
Max
Over Pressure
90
Internal Error
85
Check Consumables
80
Consumables Missing
75
Start Error
70
Parts in Place
65
Input Power
Min
Under Pressure
SERVICE
ESAB CUTMASTER 60
+
Art# A-07988
5-3