1 - IMPORTANT REMARKS
For any installation problem please contact our Customer Service
at the number +39-0172.812411 operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00.
V2 has the right to modify the product without previous
notice; it also declines any responsibility to damage or
injury to people or things caused by improper use or wrong
installation.
m
Please read this instruction manual very carefully
before installing and programming your control unit.
• This instruction manual is only for qualified technicians,
who specialize in installations and automations.
• The contents of this instruction manual do not concern the
end user.
• Every programming and/or every maintenance service
should be done only by qualified technicians.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1
(Machinery safety. electrical equipment of
machines, part 1: general rules)
EN 12445
(Safe use of automated locking devices, test
methods)
EN 12453
(Safe use of automated locking devices,
requirements)
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply. The standards require a separation of
the contacts of at least 3 mm in each pole (EN 60335-1).
• The control unit must to be mounted in a case with degree
protection IP44 or higher.
• To connect flexible or rigid pipes, use pipefittings having the
same insulation level of the case.
• After making connections on the terminal board, use one
hose clamp to fix dangerous voltage wires near the terminal
board and another hose clamp to fix safety low voltage wires
used for accessories connection; this way, in case of accidental
detachment of a conducting wire, dangerous voltage parts will
not come into contact with safety low voltage ones.
• Installation requires mechanical and electrical skills, therefore it
shall be carried out by qualified personnel only, who can issue
the Compliance Certificate concerning the whole installation
(Machine Directive 2006/42/CEE, Annex IIA).
• The automated vehicular gates shall comply with the following
rules: EN 13241-1, EN 12453, EN 12445 as well as any local
rule in force.
• Also the automation upstream electric system shall comply with
the laws and rules in force and be carried out workmanlike.
• The door thrust force adjustment shall be measured by means
of a proper tool and adjusted according to the max. limits,
which EN 12453 allows.
• We recommend to make use of an emergency button, to be
installed by the automation (connected to the control unit T1-
T2 input) so that the gate may be immediately stopped in case
of danger.
• Always remember to connect the earth according to current
standards EN 60335-1, EN 60204-1 (the control unit has two
specific W1 and W2 clamps).
• The device is not intended for use by persons (including
children) with reduced physical, sensory or mental capacities,
or lack of experience and knowledge unless they are supervised
or have been instructed in the use of the device by a person
responsible for their safety
2 - DISPOSAL
As for the installation operations, even at the end of this product's
life span, the dismantling operations must be carried out by
qualified experts.
This product is made up of various types of materials: some can
be recycled while others need to be disposed of.
Find out about the recycling or disposal systems envisaged by your
local regulations for this product category.
Important! – Parts of the product could contain pollutants or
hazardous substances which, if released into the environment,
could cause harmful effects to the environment itself as well as to
human health.
As indicated by the symbol opposite, throwing away this product
as domestic waste is strictly forbidden. So dispose of it as
differentiated waste, in accordance with your local regulations,
or return the product to the retailer when you purchase a new
equivalent product.
Important! – the local applicable regulations may envisage heavy
sanctions in the event of illegal disposal of this product.
3 - EU DECLARATION OF CONFORMITY
V2 S.p.A. hereby declare that HEAVY2 products conform to the
essential requirements established in the following directives:
• 2014/30/UE (EMC Directive)
• 2014/35/UE (Low Voltage Directive)
• ROHS2 2011/65/CE
Racconigi, 01/06/2015
V2 S.p.A. legal representative
Antonio Livio Costamagna
4 - TECHNICAL SPECIFICATIONS
MODELS
Power supply
Max motors load
Max accessories
load 24V
Working
temperature
Protection fuse
F1 = 2A (500V) / F2 = 250mA / F3 = 1A
Dimensions
200x172x80
Weight
Protecion degree
- 28 -
HEAVY2
HEAVY2-PB
HEAVY2-MB
400V (three-phase)
230V (three-phase)
230V (single-phase)
4A
20 W
-20°C ÷ +60°C
400x300x165
400x300x185
mm
mm
1600 g
4300 g
-
IP56
mm
8500 g
IP66