25.6 - TABLE OF PROGRAMMING PARAMETERS
PARAMETER
VALUE
MODE
STAN
PRES
S.PRE
OROL
T.AP
0.0"-5.0'
T.CH
0.0"-5.0'
P.APP
0-100%
T.PRE
0.5"-10.0"
NO
T.PCH
0.5"-10.0"
NO
T.AR
0.1"-2.0"
NO
R.INV
0.1"-2.0"
NO
FRE.A
SI
NO
FRE.C
SI
NO
SEN.A
0.0A-9.9A
SEN.C
0.0A-9.9A
ST.AP
PAUS
CHIU
NO
ST.CH
STOP
APRE
ST.PA
CHIU
NO
PAUS
SUBMENU
DESCRIPTION
Working mode
Standard
Dead man
Mixed
Timer
Opening time
Closing time
Partial opening
Pre-blinking time before opening
Function disabled
Pre-blinking time before closing
Pre-flashing during closing equal to
Backlash time
Function disabled
Delay at inversion
Function disabled
Brake during opening phase
Function enabled
Function disabled
Brake during closing phase
Function enabled
Function disabled
Amperometric sensor level during opening
Amperometric sensor level during closing
Start during the opening phase
The door stops and pauses
The door immediately starts closing
The door continues to open (the command is
ignored)
Start during the closing phase
The door stops and the cycle is considered as
complete
The door re-opens
Start during pause
The door starts closing
This command is ignored
The pause time is reset
T.PRE
- 47 -
DEFAULT
CHAPTER
MEMO
21
STAN
15"
16"
17
50%
13
NO
13
1.0"
23.2
NO
9.1
0.5"
9.1
SI
9.1
SI
12.1
0.0A
12.1
0.0A
19
PAUS
19
STOP
19
CHIU