1 - GENERAL SAFETY DEVICES
Our boilers are built in our plants and checked down to the
smallest detail in order to protect users and fitters from injury.
After working on the product, qualified personnel must check
the electrical wiring, in particular the stripped part of conduc-
tors, which must not stick out from the terminal board, avoid-
ing possible contact with live parts of such conductor.
This instruction manual, together with the user manual, are
integral parts of the product: make sure that they remain with
the appliance, even if it is transferred to another owner or
user, or moved to another heating system. In case of loss
or damage, please contact your local Technical Assistance
Service for a new copy.
Boiler installation and any other assistance and maintenance
operation must be carried out by qualified personnel accord-
ing to current local and national regulations.
The installer must instruct the user about the operation of the
appliance and about essential safety regulations.
This boiler must only be used for the application it was de-
signed for. The manufacturer declines all contractual and
non-contractual liability for injury to persons or animals or
damage to property deriving from errors made during instal-
lation, adjustment and maintenance and from improper use.
After removing the packaging, make sure the content is in
good conditions and complete. Otherwise, contact the dealer
from who you purchased the appliance.
The safety and automatic adjustment devices on the appli-
ance must never be modified during its lifetime, except by the
maker or dealer.
If the appliance develops a fault and/or works badly, switch it
off and do not attempt to repair it yourself.
The safety valve outlet must be connected to a suitable col-
lection and venting system. The manufacturer declines all li-
ability for any damage caused due to any intervention carried
out in the safety valve.
Dispose of all the packaging materials in the suitable contain-
ers at the corresponding collection centres.
Dispose of waste being careful not harm human health and
without employing procedures or methods which may dam-
age the environment.
B.A.I. models: the ventilation openings are vital for correct
combustion.
During installation, inform the user that:
- in the event of water leaks, the water supply must be shut off and
the Technical Assistance Service must be contacted immediately
- the operation pressure of the hydraulic system must be within 1
and 2 bar, and therefore, must no exceed 3 bar.If necessary, reset
the pressure as indicated in the paragraph entitled "Filling the
system"
- if the boiler has not been used for a long time, it is recommended
that the Technical Assistance Service performs, at least, the fol-
lowing operations:
• turn "off" the main switch of the appliance and the general
switch of the system
• close the gas and water taps on both the heating and domes-
tic hot water circuits
• drain the heating and domestic hot water circuits to prevent
freezing
In some parts of the manual, some symbols are used:
WARNING = for actions requiring special care and adequate
preparation
FORBIDDEN = for actions THAT MUST NOT be performed
For safety, always remember that:
The boiler should not be used by children or unassisted disabled
people.
It is dangerous to activate electrical devices or appliances,
such as switches, home appliances, etc., if you smell gas or
fumes. In the event of gas leaks, ventilate the room opening
doors and windows; close the gas general tap; contact the
qualified personnel from the Technical Assistance Service im-
mediately
Do not touch the boiler while barefoot or if parts of your body
are wet or damp
Before cleaning operations, disconnect the boiler from the
main power supply by turning "OFF" the two position system
switch and the main control panel switch
Do not modify safety and adjustment devices without the
manufacturer's permission and relative instructions
Do not pull, disconnect or twist the electric cables coming
out of the boiler even when it is disconnected from the main
power supply
Avoid covering or reducing the size of ventilation openings of
the installation room
Do not leave inflammable containers and substances in the
installation room
Keep packaging materials out of reach of children.
C.A.I. models: do not cover or reduce the size of the ventila-
tion openings in the room where the boiler is installed. The
ventilation openings are vital for correct combustion.

2 - BOILER DESCRIPTION

Mynute Boiler B.A.I. is a wall-mounted type B11BS boiler for heat-
ing and the production of domestic hot water, supplied with a 60
liters inox water tank. This type of appliance cannot be installed
in bedrooms, bathrooms or showers, or in rooms with open flues
without adequate ventilation.
Mynute Boiler B.S.I. is a C-type wall-mounted boiler for heating
and production of domestic hot water supplied with a 60 liters inox
water tank (28 B.S.I.) - 45 liters inox water tank (24 B.S.I.): accord-
ing to the flue gas outlet device, the boiler is classified in catego-
ries B22P, B52P, C12, C22, C32, C42, C52, C62, C82, C92, C12x,
C32x, C42x, C52x, C62x, C82x, C92x.
In configuration B22P and B52P (when installed indoors), the ap-
pliance cannot be installed in bedrooms, bathrooms, showers or
where there are open fireplaces without a proper air flow. The room
where the boiler is installed must have proper ventilation.
In configuration C, the appliance can be installed in any type of
room and there are no limitations due to ventilation conditions or
room volume.
The boiler is fitted with the following safety devices:
- Safety valve and water pressure switch intervening in cases
of insufficient or excessive water pressure (max 3 bar-min 0.7
bar).
- Temperature limit thermostat intervening by putting the boiler
into safety stop if the temperature in the system exceeds the limit
according to current local and national regulations
- Mynute Boiler B.A.I.: Fumes thermostat intervenes by block-
ing the boiler into a safety standstill status if there is a spillage of
combustion products in the hood; it is located on the right hand
tile of the vent-damper draught breaker device Intervention of
safety devices indicates a potentially dangerous boiler malfunc-
tion; contact the technical assistance service immediately.
The fumes thermostat not only intervenes for a fault in the com-
bustion products outlet system, but also with various atmospher-
ic conditions. One can therefore try to start up the boiler again
after waiting a short while (see first ignition section).
Repeated intervention of the fumes thermostat signifies
Mynute Boiler