press during 1 second M1, M2, M3, M4,M5 or M6. «MEM» becomes perma-
nent and the number of the memory appears on the display. The channel
is memorized. If the Beep function is activated a long beep confirms the
saving. In order to display the frequency press FRQ (the memory number is
hidden).
To recall a memory:
-
press MEM shortly, «MEM» is blinking.
-
press M1, M2, M3, M4, M5 or M6 shortly.
«MEM» is permanently displayed and the memory number appears on the
-
display. The memorized channel is active.
To delete a memory:
-
switch off the transceiver
-
keep the key M1, M2, M3, M4, M5 or M6 pressed and switch on the transceiver
-
the selected memory is deleted.
F - FREQUENCY BAND SELECTION
(configuration: E; d; EU;EC; U; PL)
The frequency bands have to be chosen according to the country of use.
Don't use any other configuration. Some countries need a user's licence.
See table page 52.
Proceeding: switch off the transceiver. Keep the key F pressed and switch
on again.
and the letter corresponding to the configuration are blinking.
-
In order to change the configuration, use the channel selector on the front
panel or the UP/DN keys of the microphone.
-
When the configuration is selected, press 1 second on the F key.
the letter corresponding to the configuration are continuously displayed.
At this point, confirm the selection by switching off the transceiver and then
switching it on again.
See the configurations / frequency bands table pages 48 ~ 51.
15) NB/ANL ~ SCAN ~ M3
NB/ANL
(short press)
Noise Blanker/ Automatic Noise Limiter. These filters allow reducing back
ground noises and some reception interferences. A press activates the filters
in following order: NB off, ANL off NB off, ANL on NB on, ANL off NB
on, ANL on.
«NB» and/or «ANL» are displayed in accordance with the selected configura-
tion.
(long press)
and
In FM mode only the NB filter is active.
SCAN
(long press)
Channel research: Allows activating the SCAN function (research of the chan-
nels) in an increasing way. «SCAN» is displayed. The scanning stops as soon
as there is a busy channel. The scanning automatically starts 3 seconds after
the end of the transmission and no key is activated during 3 s. The scanning
starts again in an increasing way by turning the rotary knob to the right or
pressing the UP key of the microphone, or in a decreasing way by turning
the rotary knob to the left or pressing the DN key of the microphone.
Memories research: Press MEM during the channel research cycle. The trans-
ceiver scans the active memories (M1,M2,M3,M4,M5,M6) and channels 19
and 9. Press MEM again to return to the channel research cycle.
A new long press on SCAN disables the SCAN function.
M3
See § 14 MEM.
16) 6 PIN MICROPHONE PLUG
The plug is located on the front panel of the transceiver and makes the set-
ting of the equipment into the dashboard easier.
See cabling diagram page 50.
17) PTT
Transmission key, press to transmit a message,
to listen to an incoming communication.
BEEP
(changing the channel, keys etc.)
In order to activate the BEEP function, turn on the transceiver by pressing
the UP key of the microphone. «BP» is displayed. In order to disable the func-
tion, turn the transceiver on by pressing the DN key of the microphone. «BP»
disappears.
A) POWER SUPPLY (13.2V)
B) ANTENNA CONNECTOR (SO-239)
C) JACK FOR OPTIONAL VOX MIKE (2.2 KΩ Electret, Ø 2.5 mm)
D) JACK FOR LOUDSPEAKER PUBLIC ADDRESS (8 Ω, Ø 3.5 mm)
E) JACK FOR EXTERNAL LOUDSPEAKER (8 Ω, Ø 3.5 mm)
34
is displayed and release