7.7. ALARMS/ERRORS

7.7.0. ALARM ABSENCE COMUNICATION BETWEEN BASE AND KEYBOARD
===> CONTACT TECHNICAL ASSISTANCE
Verify connections, ignite and extinguish the machine detaching the feeding

7.7.1. HIGH TEMPERATURE ALARM

During the positive (negative), the alarm part when the temperature cabinet the values sets up.
Alarm code AL1 will fl ash on DISPLAY 1.
The buzzer (optional) sounds but can be stopped by pressing a button. When the temperature falls
by below the alarm threshold, the alarm is automatically cancelled.

7.7.2. LOW TEMPERATURE ALARM

During the positive (negative), the alarm part when the temperature cabinet the values sets up.
Alarm code AL2 will fl ash on DISPLAY 1.
The buzzer (optional) sounds, but can be stopped by pressing a button. When the
temperature rises by P01 ºC above the alarm threshold, the alarm is automatically cancelled.

7.7.3. DOOR OPEN ALARM

If the door is open for more than two minutes after the start of the blast chill/shock freeze, the
compressor stops and the code AL3 will fl ash on DISPLAY 1.
7.7.4. GENERIC ALARM ===> CONTACT TECHNICAL ASSISTANCE
When generic alarm AL4 is activated, the blast chill cycle in progress will be immediately terminated.
7.7.5. TIME-OUT ALARM
If the blast chill or shock freeze phase in progress does not terminate within the set time, code AL5
will fl ash on DISPLAY 1.

7.7.6. BLACKOUT ALARM

If a blackout occurs during a blast chill cycle, the machine remembers the cycle and phase it was
performing when it switched off.
In cycles with food probes, the machine also remembers which probes were inserted or whether it is
necessary to perform a probe insertion test. Blast chill time tolerance is 10 minutes.
Code AL7 will fl ash on DISPLAY 1.
The buzzer (optional) sounds, but can be stopped by pressing a button. If the button is pressed
again, the display disappears.
7.7.7. CABINET PROBE ALARM ===> CONTACT TECHNICAL ASSISTANCE
The cabinet probe measures the temperature of the cabinet, which is indicated on DISPLAY 2.
If the probe is defective, a cabinet probe alarm and buzzer (optional) are activated and error code
ER1 fl ashes on the DISPLAY 1.
The buzzer (optional) sounds, but can be stopped by pressing a button.
Once the fault is remedied, the alarm cancels automatically.
- In the case of a faulty cabinet probe, it is nevertheless possible to start or continue a blast chill pro-
gramme with timer.
- A set temperature blast chill programme not yet started, will convert the setting to time.
- If the food probe is not inserted, a set temperature blast chill programme in progress will convert
the setting to time and the compressor check will be performed on the food probe instead of the
cabinet probe.
- A set temperature blast chill programme in progress with food probe inserted, turns the compressor
on and off on the basis of times memorised previously in blast chill or conversation phases.