Installation; Ssembling The Ccessories; Ontrols And Onnection To The Ains Water Upply; Hecks And Onnection To The Ains Electricity Upply - EMAK PW 160 Manual De Istrucciones

Ocultar thumbs Ver también para PW 160:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
4 I
NSTALLATION
See Fig. A at the front of these operating and maintenance instructions.
4.1 A
SSEMBLING THE
a) Insert the lance hose (11) on the water gun (8) and tighten.
b) Mount the accessory support (26) on the handlebar (30); mount the knob and the lever (13) on
the hose reel (6) (only PW 170C - IP 1700S).
c) Mount the hose (25) between the hose reel and the water cleaner, by tightening the two fast
coupling connectors; release the locking device (24) of the hose reel (6); unroll the hose
quantity (7) that is necessary by rotating the hose reel by means of the knob (13), then lock
the device (24) (only PW 170C - IP 1700S).
d) Unroll the high-pressure hose (7), connect the fast coupling connector to the water outlet
connector (5), screw and tighten (only PW 160 - IP 1600).
e) Screw the end of the high-pressure pipe (7) (side without fast coupling for PW 160 - IP 1600)
on the water gun thread (8) and tighten with two 17-mm box wrenches (not supplied).
f) Insert the water suction filter (15) into the water suction connector (14) and tighten it on the
water inlet connector of the water cleaner.
4.2 C
ONTROLS AND
WARNING
• The water supply must be able to guarantee the adequate delivery of water flow to the high
pressure cleaner; refer to the table of technical specifications.
In case of doubt, contact a Skilled Technician.
• Do not supply the water cleaner with water at a temperature in excess of 50°C/122°F or below
5°C/41°F.
• The pressure of the water supply must not be in excess of 8 bar/116 psi.
• Do not operate the high pressure cleaner with a priming depth in excess of 0 m / 0 ft.
• Do not operate the high pressure cleaner if it is not connected to a water supply.
• Do not supply the high pressure cleaner with salt water or water containing impurities. In this
event, run the high pressure cleaner for a few minutes with clean water.
fi«
CAUTION
• Follow current regulations for connection to the mains water supply in the country where the
water cleaner is installed.
4.3 C
C
HECKS AND
fi«
CAUTION
• A Skilled Technician must check that the electrical supply complies with the data indicated
on the identification label (18) on the high pressure cleaner. It is especially important that the
supply voltage does not differ more than +-5% from that indicated on the label.
• All connections to mains electricity must be carried out by a Qualified Eletrician according to
IEC 364 regulations or the equivalent standard in the country where the high pressure cleaner
is to be used. It is especially important that the current outlet where the high pressure cleaner is
connected is provided with an earth conductor and a suitable fuse (according to the size indicated
on the identification label and in the table of technical specifications), and must be protected by
a magneto-thermal differential circuit breaker, whose sensitivity is not in excess of 30 mA.