Tabla de contenido

Publicidad

4 I
NSTALLATION
4.1 A
SSEMBLING THE
a) Insert the handling bar (3) onto the body of the high pressure cleaner. Make sure you fully insert the bar
into the high-pressure cleaner's body (the front surfaces must be aligned with one another). Secure the bar
with the 2 screws supplied (cross head screwdriver not supplied). Step A in Fig. 2
b) The PW 135C – IP 1350S – PW 145C - IP 1450S are supplied with a lance hose (28) which can be fi tted
with a standard nozzle support head (27), or a head with a rotating nozzle (18), using a bayonet mount.
Depending on the job to be done, fi t one of the two heads by inserting it into the lance hose and turning it
clockwise until it clicks securely onto the coupling. Now block it in place with the Securfi x ring nut (11),
by turning it clockwise. Step I in Fig. 2.
To remove the head, turn the Securfi x ring nut (11) anti-clockwise and remove it. Keep the head pressed
down into the lance hose housing and turn it anticlockwise until it is released, then remove it completely.
Step H in Fig. 2.
c) Unroll the high-pressure hose (23), connect the quick-fi t connector (24) to the water outlet connector (8),
screw down and secure. Step C in Fig. 3.
d) Screw the end of the high pressure hose (23) (the end without the quick fi t connector) onto the thread of
the spray gun (14) and secure it tightly using two 17 mm socket keys (not supplied). Step D in Fig. 3.
4.2 C
C
HECKS AND
CAUTION
• The water supply must be able to guarantee the adequate delivery of water fl ow to the high pressure cleaner;
refer to the table of technical specifi cations.
In case of doubt, contact a Skilled Technician.
• Do not supply the water cleaner with water at a temperature in excess of 40°C/98°F or below 5°C/41°F.
• The pressure of the water supply must not be in excess of 8 bar/116 psi.
• Do not operate the high pressure cleaner with a priming depth in excess of 0 m/0 ft.
• Do not operate the high pressure cleaner if it is not connected to a water supply.
• Do not supply the high pressure cleaner with salt water or water containing impurities. In this event, run
the high pressure cleaner for a few minutes with clean water.
WARNING
• Follow current regulations for connection to the mains water supply in the country where the water cleaner
is installed.
4.3 C
C
HECKS AND
WARNING
• A Skilled Technician must check that the electrical supply complies with the data indicated on the
identifi cation label (7) on the high pressure cleaner. It is especially important that the supply voltage does
not differ more than ±5% from that indicated on the label.
• All connections to mains electricity must be carried out by a Qualifi ed Eletrician according to IEC 364
regulations or the equivalent standard in the country where the high pressure cleaner is to be used. It is
especially important that the current outlet where the high pressure cleaner is connected is provided with an
earth conductor and a suitable fuse (according to the size indicated on the identifi cation label and in the table
of technical specifi cations), and must be protected by a magneto-thermal differential circuit breaker, whose
sensitivity is not in excess of 30 mA.
• If the power supply cable is too short, an extension cord can be used provided it is not longer than 10
m/32.8 ft, the section of the wires is at least 1,5mm² and the plug and the socket are waterproof. Contact
a Qualifi ed Eletrician so that all these requirements are followed.
The use of unsuitable extension cords can be dangerous.
22
A
CCESSORIES
ONNECTION TO THE
ONNECTION TO THE
M
W
S
AINS
ATER
UPPLY
M
E
AINS
LECTRICITY
S
UPPLY

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pw 135cPw 145cIp 1200sIp 1350sIp 1450s

Tabla de contenido