Table Of "Burners" Techincal Data; Disposals For Converting And Installing For Other Types Of Gas; Replacing The Main Burner Nozzle; Replacing The Pilot Burner Nozzle - Lotus BRF-94G Guia Para La Intalación E Instrucciones De Uso

Cacerolas a gas para uso profesional
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Burner 9 kW min. 3,6 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Burner 18 kW min. 7,25 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm

DISPOSALS FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS

Our appliances are tested and regulated with liquid gas /see plate).
The conversion or adaptation to another type of gas must be carried out by a specialized technician. The nozzles for the
various types of gas are supplied in a packet and are marked in hundredths of mm (see table of "burners" technical
data).
Remove the control panel's front securing screws (see fig. G), remove the ignition cable from the piezoelectric
lighter (fig. D)
With a suitable spanner, unscrew the nozzle (fig. F pos 1) and put the appropriate one in its place (see the "Burner
technical data" table).
The main burner needs no adjustment for the primary air.
The flame of the pilot burner has fixed air.
The only job to do is change the nozzle (fig. E pos. 2) according to the type of gas.
In this case you have to unscrew the screws as specified above and, with an appropriate spanner, unscrew the fitting and
change the nozzle (fig. E pos. 2) with a suitable one. With the right nozzle, the flame should envelope the thermocouple
(fig. E pos. 3).

Important!

Once the appliance has been converted to work with a different type of gas, the technical specification plate has to be
updated, writing on it the type of gas the appliance has been converted to.
The appliance contains the instructions necessary for use.
Check the appliances for gas leaks.
Examine the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of
the pilot burner.
Check the lighting and flame of the main burner.
We urge the user to follow the instructions when using the appliance.
With prolonged use of the appliance, it is indispensable to carry out regular maintenance for the safe functioning of the
appliance; we therefore recommend drawing up a contract for after sales service.
GB

TABLE OF "BURNERS" TECHINCAL DATA

12.8 kWh/KG
G30
BUTANE
28 mbar
145A
kg/h 0,710
open (40)
210A
kg/h 1,420

REPLACING THE MAIN BURNER NOZZLE

REPLACING THE PILOT BURNER NOZZLE

CHECKING FUNCTIONING

MAINTENANCE

IE
12.8 kWh/KG
G31
PROPANE
37 mbar
145A
100
100
25
25
kg/h 0,699
open (40)
210A
150
150
25
25
kg/h 1,399
35
35
30
3
9.45 kWh/m
st.
G20
NATURAL GAS
20 mbar
230
adjustable
41
3
m
st./h 0,952
25
340
adjustable
41
3
m
st./h 1,905
30

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Brf-98g

Tabla de contenido