Servicing the Fluid Section
Use the following procedures to service the valves and repack the
fluid section. Perform the following steps before performing any
maintenance on the fluid section.
1. Loosen and remove the four front cover screws. Remove the
front cover.
2. Stop the sprayer at the bottom of its stroke so that the piston
is in its lowest position.
3. Perform the Pressure Relief Procedure and unplug the sprayer.
Before proceeding, follow the Pressure relief
Procedure outlined previously in this manual.
additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. always unplug the sprayer before
servicing!
4. Unscrew the return hose assembly from the pump block.
Remove the retaining clip from the bottom of the foot valve
housing. Remove the siphon assembly.
5. Tilt the sprayer back for easy access to the fluid section.
Servicing the Valves
The design of the fluid section allows
access to the foot valve and seat as well
as the outlet valve and seat without
completely disassembling the fluid
section. It is possible that the valves
may not seat properly because of
debris stuck in the foot valve seat or
outlet valve seat. Use the following
instructions to clean the valves and
reverse or replace the seats.
1. Remove the pusher stem clip
and slide the pusher stem
housing from the foot valve
housing.
2. Using a wrench, loosen and
remove the foot valve housing
from the pump block.
3. Clean out any debris in the foot
valve housing and examine
the valve housing and seat. If
the seat is damaged, reverse or
replace the seat.
4. Using a 5/16" hex wrench, loosen and
remove the outlet valve retainer from
the piston rod.
NOTE: always service the outlet valve
with the piston rod attached to
the pump. This will prevent the
piston rod from rotating during
disassembly of the outlet valve.
5. Clean out any debris and examine the
outlet valve housing and seat. If the
seat is damaged, reverse or replace the
seat.
6. Remove, clean, and inspect the outlet cage, crush washer, and
outlet valve ball. Replace if they are worn or damaged.
NOTE: The outlet cage always must be used with the
crush washer. They are included together in the
repacking kit as assembly P/N 704-642.
7. Reassemble the valves by reversing the steps above.
NOTE: During reassembly of the outlet valve, apply one
drop of Loctite (included in the repacking kit) to
the threads of the outlet valve retainer before
threading it into the piston rod. Then, torque the
retainer to 144 in./lbs. (12 ft./lbs.).
© Titan Tool Inc. All rights reserved.
repacking the Fluid Section
1. Remove the foot valve assembly using the steps in the
"Servicing the Valves" procedure above.
NOTE: The outlet valve does not need to be disassembled
from the piston rod for this procedure.
2. Using 3/8" a hex wrench,
loosen and remove the
two pump block mounting
screws.
3. Pull the pump block down
approximately 1/2" from
the pump housing.
4. Slide the pump block and
piston rod forward until
the piston rod is out of
the T-slot on the slider
assembly.
5. Slide the piston rod out
through the bottom of the
pump block.
Pump
6. Loosen and remove the
block
retainer nut and piston
guide from the pump
Bushing
block.
Foot valve
7. Remove the upper and
seal
lower packings from the
Inlet cage
pump block.
8. Clean the pump block and
Foot valve
ball
install the new upper and
lower packings. Refer to
Foot valve
the illustration below for
seat
proper packing orientation.
PTFE
O-ring
Install upper packing
Foot valve
with raised lip and O-ring
O-ring
Pusher
Raised Lip
stem
housing
9. Inspect the piston rod for wear and replace if necessary.
10. Reassemble the outlet valve assembly into the piston rod.
Tighten the outlet valve retainer with a wrench until secure.
Piston rod
Outlet cage
NOTE: use the T-slot on the slider assembly to hold the
Crush
piston rod in position while securing the outlet
washer
valve retainer.
Outlet valve
ImPOrTaNT: Never use a wrench on the piston itself. This could
ball
cause damage to the piston and cause leakage.
Outlet valve
11. Insert the piston guide into the retainer nut. Thread the
seat
retainer nut into the pump block until it is hand tight.
Outlet valve
12. Slide the piston guide tool (included in the repacking kit) over
retainer
the top of the piston rod and insert the piston rod through
the bottom of the pump block. Using a rubber mallet, tap
the bottom of the piston rod lightly until the piston rod is in
position in the pump block.
NOTE: coat the piston guide tool and the piston rod with
grease before inserting them into the pump block.
13. Using a wrench, tighten the retainer nut securely.
14. Slide the top of the piston rod into the T-slot on the slider
assembly.
15. Position the pump block underneath the pump housing and
push up until it rests against the pump housing.
16. Thread the pump block mounting screws through the pump
block and into the pump housing. Tighten securely.
17. Reassemble the foot valve assembly into the pump block.
11
T-Slot
Install lower packing
with the beveled
facing down.
edge facing up.
O-Ring
English
Slider
assembly
Retainer
nut
Piston
guide
Upper
packing
Pump
block
Pump block
mounting
screw
Lower
packing
Piston rod
Beveled Edge