Disassembly And Disposal; Maintenance; Technical Data - SICK WLA26 Instrucciones De Operación

Ocultar thumbs Ver también para WLA26:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
10

DISASSEMBLY AND DISPOSAL

10
Disassembly and disposal
11

Maintenance

12

Technical data

Sensing range (with reflector PL80A)
Light spot diameter/distance
12
LED indicator/fault pattern
Not all blue LEDs light up.
Yellow LED flashes
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
This symbol on the product, its package or in this document, indicates
that a product is subject to these regulations.
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
Cause
a)
Insufficient alignment
b)
Contamination of the
optical surfaces
c)
Particles in the light
beam
d)
Distance between sen‐
sor and reflector is too
large
e)
Reflector is not suitable
Distance between sensor and
reflector is too large / light
beam is not completely
aligned to the reflector /
reflector is not suitable / Front
screen and/or reflector is con‐
taminated.
WLA26P
0 m ... 12 m
Ø 80 mm (5 m)
Measures
3. Check electrical connections
a)
Check alignment
b)
Cleaning of the optical
surfaces (sensor and
reflector).
c)
Avoid contamination in
the air as far as possible
d)
Check sensing range
e)
SICK reflector is recom‐
mended
Check sensing range / check
alignment / SICK reflector is
recommended / Cleaning of
the optical surfaces (sensor
and reflector).
8020357.14CS | SICK
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido