Specification Installation Fitting stacking plates and wall plates Fixing procedures Switching on Temperature control Warning Servicing by Techne and their Agents OPERATION The tubes The Hybrigene Basic Protocol for Southern Hybridisations When the Protocol is Finished TECHNICAL INFORMATION Operator Maintenance...
Página 4
H y b r i g e n e O P E R A T O R ’ S M A N U A L...
Página 5
H y b r i g e n e O P E R A T O R ’ S M A N U A L NOTES...
Servicing under this guarantee should be obtained from the material. supplier. Techne have taken great care in the design of these units to Notwithstanding the description and specification(s) of the units protect operators from hazards, but users should pay attention to contained in the Operator’s Manual, Techne hereby reserves...
Techne a apporté un soin tout particulier à la conception de ces Malgré la description et les spécifications de l’appareil données appareils de façon à assurer une protection maximale des dans le manuel de l’utilisateur, Techne se réserve le droit...
Defekt keine unsachgemäße Handhabung, Fahrlässigkeit oder und brennbare Materialien können sich leicht entzünden. ein Unfall zugrundeliegt. Der unter diese Garantie fallende Service Techne hat bei der Konstruktion dieses Gerätes sehr darauf wird vom Lieferanten geleistet. geachtet, daß der Bediener vor Gefahren geschützt ist. Dennoch...
Mientras combustibles. se encuentre bajo garantía las revisiones las debe llevar a cabo Techne ha puesto gran cuidado en el diseño de estos aparatos el proveedor. para proteger al usuario de cualquier peligro; aún así se deberá...
Questo Manuale è stato realizzato esclusivamente a vantaggio · Utilizzare con attenzione e indossare guanti protettivi; dei clienti della Techne e in alcun modo potrà essere utilizzato · Non mettere vicini oggetti caldi o oggetti infiammabili; come garanzia, condizione o rappresentazione concernente la ·...
Initial Checks When you receive your new Hybrigene remove all the packing. Check the unit for any transit damage. If there is any transit damage at all inform Techne Sales Department or your Techne dealer immediately. When unpacking the unit, check that the following have been removed from the packing: a power cable;...
# Large tubes are fitted with 70°C seals, seals part number 6101488 are required to work to 100°C. For the Hybridisation Tubes see the list under Accessories Working conditions The Hybrigene is designed to work safely under the following conditions: Ambient temperature range 5°C to 40°C Humidity Up to 95% relative humidity, non-condensing Note: The control specifications are quoted at an ambient temperature of 20°C.
Página 13
H y b r i g e n e O P E R A T O R ’ S M A N U A L Speed control knob Controller...
Insert some liquid into a tube and place the tube in the Hybrigene. Adjust the feet by unscrewing them anticlockwise slightly until the unit is level. Check the level by putting the tube in different positions.
H y b r i g e n e O P E R A T O R ’ S M A N U A L Fitting stacking plates and wall plates on a Hybrigene A trained technician should carry out this work only after reading the full instructions.
Three Hybrigenes • If you have three units repeat the process for the top two units. We recommend that you fix the top Hybrigene to the wall for safety. Wall Fixing • Use the three screws to attach a support bracket to the top of the top unit.
H y b r i g e n e O P E R A T O R ’ S M A N U A L Switching On Once your Hybrigene is connected to a power supply, switch it on using the power switch next to the power inlet socket on the rear panel.
Servicing by Techne and their Agents Please note that neither Techne nor any of their agents can accept the return of ANY GLASSWARE from these units. If the unit is returned it must be thoroughly decontaminated and a CERTIFICATE OF CLEANLINESS returned with the unit.
Remove the tube end cap which has the holes in it. Place the filters in the tube and replace the end cap. A small quantity of Techne O-ring grease, see the list of accessories, must be smeared on the seal to facilitate the insertion of the end cap.
Página 20
H y b r i g e n e O P E R A T O R ’ S M A N U A L Small Tube (3 x 44mm dia) assembly Unscrew the tube end cap. Place the filters in the tube and replace the end cap. Remove the spindle cap and the liquids appropriate to the protocol may then be added through the hole in the spindle using a syringe.
H y b r i g e n e O P E R A T O R ’ S M A N U A L The Hybrigene Insert the tubes or tube holder into the Hybrigene ensuring that they rotate freely and engage on the drive rollers.
H y b r i g e n e O P E R A T O R ’ S M A N U A L BASIC PROTOCOL FOR SOUTHERN HYBRIDISATIONS * INSERTION OF FILTERS Place a wet or moist filter, DNA side facing inwards, into a hybridisation tube and allow it to adhere to the glass.
Techne Service department giving as much information as possible to help diagnose the fault. Please remember to return the unit in its original packing, Techne accept no responsibility for damage to units which are not properly packed: if in doubt, contact your supplier.
Página 24
Before cleaning your unit ALWAYS disconnect from the power supply and allow to cool. You can clean the case of the Hybrigene with a cloth dampened in soapy water. No part of the unit should be immersed in solvents. Do not use acetone or abrasive cleaners.
H y b r i g e n e O P E R A T O R ’ S M A N U A L Accessories and Spares The following may be purchased from Techne or their dealers. All Techne tubes are made from Borosilicate glass...
Página 26